6. Maintenance and Service
Maintenance and Cleaning
Before any work on the machine itself, pull the mains plug.
l
For safe and proper working, always keep the machine and
l
ventilation slots clean.
The retracting blade guard must always be able to move freely
l
and retract automatically. Therefore, always keep the area
around the retracting blade guard clean. Remove dust and
chips by blowing out with compressed air or with a brush.
Saw blades that are not coated can be protected against
l
corrosion with a thin coat of acid-free oil. Before use, the oil must
be removed again, otherwise the wood will become soiled.
Resin and glue residue on the saw blade produces poor cuts.
l
Therefore, clean the saw blade immediately after use.
If the machine should fail despite the care taken in
l
manufacturing and testing procedures, repair should be carried
out by an after-sales service centre for STAYER IBÉRICA S. A
tools.
After-sales service and customer assistance
Our after-sales service responds to your questions concerning
maintenance and repair of your product as well as spare parts.
Exploded views and information on spare parts can also be found
under: www.grupostayer.com
Disposal
The machine, accessories and packaging should be sorted for
environmental-friendly recycling.
Only for EC countries:
Do not dispose of power tools into household waste!
According the European Guideline 2002/96/EC for Waste
Electrical and Electronic Equipment and its
implementation into national right, power tools that are no
longer usable must be collected separately and disposed
of in an environmentally correct manner.
Subject to change without notice.
EC Declaration of Conformity
The undersigned:
STAYER IBERICA, S.A.
Whit address at:
Calle Sierra de Cazorla, 7
Área Empresarial Andalucía - Sector 1
28320 PINTO (MADRID)
Tel.: +34 91 691 86 30 / Fax: +34 91 691 91 72
CERTIFIES
That the machine:
Type:
CIRCULAR SAW
Model:
CP190B
We declare under our sole responsibility that the product described
under "Technical Data" is in conformity with the following standards or
standardization documents: EN 60745, EN 61000 according to the
provisions of the directives 2004/108/CE, 2006/42/CE.
Ramiro de la Fuente
Director Manager
ENGLISH
13
13