TROUBLE
The pump is running but
maximum pressure is
not obtained
Fluctuating pressure
Pressure decreases
Excessive noise
Presence of water in oil
Water dripping from under pump
Oil leakage
The motor hums but does not run
when turned on
The motor does not start when
switched on
The motor stops
12 - TROUBLE SHOOTING
(FOR QUALIFIED PERSONNEL)
CAUSE
Air sucked into pump
Worn or dirty valves
Unloader packings worn
Nozzle worn or incorrect
Piston packings worn
Dirty filter
Damaged, dirty or clogged valves
Air is being sucked
Worn packings
Dirty filter
Worn nozzle
Dirty or stuck valves
Bypass packings worn
Piston packing worn
Dirty filter
Air suction
Damaged, dirty or stuck valves
Worn bearings
Water temperature too high
Dirty filter
Piston packings and oil seals worn
High air humidity
Piston packings worn
Packing o-rings worn
Oil seals worn
System voltage is lower to the
minimum advised
The pump is stuck or frozen
Extension cord incorrect
The plug is not well connected
No power supply
The thermal protector has tripped
due to overheating
20
REMEDY
Check suction hose and fittings
Clean or replace
Check and/or replace
Check and/or replace
Check and/or replace
Check and/or clean
Check, clean and/or replace
Check suction hose and fittings
Check and/or replace
Check and/or clean
Substitute nozzle
Check, clean and/or replace
Check and/or replace
Check and/or replace
Check and/or clean
Check suction hose and fittings
Check, clean and/or replace
Check and/or replace
Lower water temperature to
under 60°C
Check and/or clean
Check and/or replace
Change oil twice as frequently
as that advised
Check packings
Replace O.R.
Replace oil seal
Check that your power source
is adequate
See page 17
Check the extension cord
table on page 11
Check plug, cord and switch
- Release the gun trigger to the
off position and engage the
safety lock.
- Turn the selector knob to the
"0" (OFF) position in order to
avoid accidental restarts.
- Check that the mains voltage is
the prescribed one.
- Let the motor cool for a few
minutes before restarting the
unit, by turning the switch to the
"I" (ON) position and pulling the
gun trigger. If the unit does not
start, bring back the switch to
the "0" (OFF) position.
- Repeat the operation until the
unit starts.