8 Malfunctions
Malfunction
Floor saw does not operate
Saw blade jammed
Saw blade does not rotate even
though the motor is running
Feed not working
Motor running off centre
Floor Saw FSG620
Possible cause
EMERGENCY STOP switch has been pressed.
Saw blade is jammed in the cutting material
Belt tension too slack
Pulling pin on the anchoring flange has
sheared off
Operation of the control rods impaired
Defective hydrostat
Defective chain
Main motor belt slipping
Wrong fuel
Oil filter blocked
TYROLIT Hydrostress AG
Solution
► Release EMERGENCY STOP switch.
► Reverse the floor saw.
► If necessary release the saw blade by
rocking.
► If necessary stop the motor, disassemble
the saw blade and release this
individually from the cutting material.
► Tension or replace belt.
► Mount new anchoring flange.
► Check control rods and repair as
necessary.
► Check hydrostat and if necessary have
this repaired by a TYROLIT Hydrostress
engineer.
► Have the chain replaced by a TYROLIT
Hydrostress engineer.
► Check belt for wear and if necessary
have this replaced by a TYROLIT
Hydrostress engineer.
► Increase belt tension as necessary.
► Switch off motor immediately and
change fuel.
► Have oil filter changed.
Page 19

Publicidad

Tabla de contenido
loading