Safety; Fire Prevention Measures - Jøtul F 370 Advance Serie Instrucciones Para Instalación

Ocultar thumbs Ver también para F 370 Advance Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ENGLISH
Technical data in acc. with EN 13240 / NS 3058
Nominal heat output:
Flue gas volume:
Chimney draught, EN 13240:
Recommended negative pressure
in smoke outlet:
Effi ciency:
CO emissions (13% O 2 ):
CO emissions (13% O 2 ):
NOx at 13% O 2 :
OGC @ 13 % O 2 :
Air consumption:
Chimney temperature, EN 13240:
Dust:
Particle emission NS 3059:
Type of fuel:
Recommended log length:
Max. log length:
Fuel consumption:
Max. kindling amount:
Nominal kindling amount:
Operation:
Intermittent combustion in this context means normal use of the
fireplace, i.e. fuel is added as soon as the fuel has burnt down to
a suitable amount of embers.

3.0 Safety

NB! To guarantee optimal performance and safety, Jøtul
recommends that its stoves are fi tted by a qualifi ed
installer (see www.jotul.com for a complete list of dealers).
Any modifi cations to the product may result in the product
and safety features not functioning as intended. The same
applies to the installation of accessories or optional extras not
supplied by Jøtul. This may also be the case if parts that are
essential to the functioning and safety of the fi replace have
been disassembled or removed.
In all these cases, the manufacturer is not responsible or liable
for the product and the right to make a complaint becomes null
and void.
The Clean Air Act
"The Clean Air Act 1993 and Smoke Control Areas"
Under the Clean Air Act local authorities may declare the
whole or part of the district of the authority to be a smoke
control area. It is an offence to emit smoke from a chimney of
a building, from a furnace or from any fi xed boiler if located in a
designated smoke control area. It is also an offence to acquire
an "unauthorised fuel" for use within a smoke control area
unless it is used in an "exempt" appliance ("exempted" from
the controls which generally apply in the smoke control area).
The Secretary of State for Environment, Food and Rural
Affairs has powers under the Act to authorise smokeless
fuels or exempt appliances for use in smoke control areas in
England. In Scotland and Wales this power rests with Ministers
in the devolved administrations for those countries. Separate
legislation, the Clean Air (Northern Ireland) Order 1981,
applies in Northern Ireland. Therefore it is a requirement that
fuels burnt or obtained for use in smoke control areas have
been "authorised" in Regulations and that appliances used to
burn solid fuel in those areas (other than "authorised" fuels)
have been exempted by an Order made and signed by the
4
6,0 kW
6,3 g/s
12 Pa
14-16 Pa
78%@6,8 kW
0.06%
731 mg / Nm 3
93 mg / Nm 3
45 mg/Nm 3
6,1 litre/sec or 22 m 3 /h
275 o C
<4 mg/Nm 3 @13%O 2
2,9 g / kg
Wood
27-30 cm
33 cm
2.1 kg/h
2.0 kg
1.6 kg
Intermittent
Secretary of State or Minister in the devolved administrations.
Further information on the requirements of the Clean Air Act
can be found here : http://smokecontrol.defra.gov.uk/
Your local authority is responsible for implementing the Clean
Air Act 1993 including designation and supervision of smoke
control areas and you can contact them for details of Clean Air
Act requirements".
Your local authority is responsible for implementing the Clean
Air Act 1993 including designation and supervision of smoke
control areas and you can contact them for details of Clean Air
Act requirements"

3.1 Fire Prevention Measures

There is a certain element of danger every time you use
your fi replace. The following instructions must therefore be
followed:
The minimum safety distances when installing and using
the fi replace are given in fi g. 1. The specifi ed distance to
fl ammable materials, applies to this stove. The stove must
be installed with a CE approved fl ue. The distance of the
fl ue pipe to combustible materials must also be observed.
Ensure that furniture and other fl ammable materials are not
too close to the fi replace. Flammable materials should not
be placed within 1100 mm of the fi replace.
Allow the fi re to burn out. Never extinguish the fl ames with
water.
The fi replace becomes hot when lit and may cause burns
if touched.
Only remove ash when the fi replace is cold. Ash can contain
hot embers and should therefore be placed in a non-
fl ammable container.
Ash should be placed outdoors or be emptied in a place
where it will not present a potential fi re hazard.
In case of chimney fi re:
Close all hatches and vents.
Keep the fi rebox door closed.
Check the loft and cellar for smoke.
Call the fi re service.
Before use after a fi re an expert must check the fi replace
and the chimney in order to ensure that it is fully functional.
3.2 Floor
Foundation
You need to make sure the foundation is suitable for a fi replace.
See "2.0 Technical Data" for specifi ed weight.
We recommend the removal of any fl ooring that is not attached
to the foundation ("fl oating fl oors") beneath the installation.
Requirements for protection of wooden
fl ooring beneath the fi replace
Jøtul F 370 Advance Series has a heat shield underneath
which protects the base from radiation.
an integrated fl oor protection and may therefore be placed
directly on a wooden fl oor.
The product has

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

F 371 advanceF 371 advance htF 373 advanceF 377 advanceF 377 advance htF 378 advance ... Mostrar todo

Tabla de contenido