EQUATION EQH-70 Instrucciones Para Instalación, Uso Y Mantenimiento página 32

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Model: EQH-70 Built-in Fireplace.
Maximum Power.
Power transmitted to the atmosphere (useful)
Mass of fuel / hour
Average gas temperature
Average CO concentration at 13% O2
Performance
Accepts logs of the following length:
Fumes ring
Metal Chimney
Recommended chimney height
Brickwork chimney, at least (approx.)
Smoke outlet
Minimum draw recommended
Primary Air Control
Weight
Model: EQH-80 Built-in Fireplace.
Maximum Power.
Power transmitted to the atmosphere (useful)
Mass of fuel / hour
Average gas temperature
Average CO concentration at 13% O2
Performance
Accepts logs of the following length:
Fumes ring
Metal Chimney
Recommended chimney height
Brickwork chimney, at least (approx.)
Smoke outlet
Minimum draw recommended
Primary Air Control
Weight
WARNING! Your EQH built-in fireplace should not be used as an incinerator
and no other types of fuel should be used (plastic, coal...). Use
recommended materials only.
Recommended fuel:
Haya
Encina
Pino
Draw = 2 mmca.
( )
) ) " )
VIII.- TECHNICAL DATA.
LOG (Oak, beechwood...)
LOG (Oak, beechwood...)
Dimensiones L x Ø (approx)
FUEL
50cm x 7cm
50cm x 7cm
50cm x 7cm
$
EQH-70
EQH-80
60cm x 7cm
60cm x 7cm
60cm x 7cm
) '
17.5 KW
12.5 KW
4 kg
309 ºC
0.157
71.3%
520 mm.
175 mm.
175 mm.
5 to 6 metres
200 x 200 mm.
Vertical
12 Pa
Manual regulation
130 kg
20,7 KW
14.5 KW
4,75 kg
340 ºC
0.18
70,17.3%
620 mm.
200 mm.
200 mm.
5 to 6 metres
250 x 250 mm.
Vertical
12 Pa
Manual regulation
147 kg

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Eqhr-70Eqh-80Eqhr-80

Tabla de contenido