Assembly

GB
4.
Assembly
4.1

Assemble bus module CIB C

Fig. 3: Assembly of the bus module CIB C and the assembly sheet
20
Isolate electrical supply before start of work!
Assembly EUROCONDENSE two
• Remove top casing panel. The installation location of the bus
module CIB C becomes accessible after removing the control pa-
nel cover.
Assembly PARAMOUNT two
• Remove the boiler front door and hinge down out the boiler con-
trol panel. The installation location of the bus module CIB C be-
comes accessible after removing the control panel cover.
Assemble bus module CIB C
• Let the bus module CIB engage on the control and regulating
centre BMU and insert the 6-pole ribbon cable into the plug-in
location "bus clip-in" on the control and regulating centre BMU
(fig. 3).
• Insert 2-pole plug for the CIM-mains connection at X1.2 (mains
clip-in) of BMU.
Bus module CIB
Plug in protective earthed conductor
• Plug in protective earthed conductor (green-yellow) with rec-
tangular connector into the protective earthing cable support
terminal of the boiler control panel (see wiring diagram).