Installation Rules - Vimar ELVOX Petrarca 6020 Manual Do Instalador

Ocultar thumbs Ver también para ELVOX Petrarca 6020:
Tabla de contenido

Publicidad

The instruction manual is downloadable from the site
EN
www.vimar.com
Petrarca
Description
PETRARCA series monitor Art. 6020 (6000), 6023 (6003)
can work in conjunction with interphones 6200 - 6201 -
6204 for video door entry systems series "SOUND SYS-
TEM", "C.A. CALL", "DIGIBUS" and with telephone type
3562. In addition, the monitor may be installed on its own
using the corresponding accessories.
Technical characteristics of Art. 6020
- Slim-line surface wall-mounted monitor B/W with 3,5"
flat screen.
- Minimum supply voltage: 15 Vdc (maximum 20 Vdc)
- Video signal standard: CCIR with 625 lines and 50
frames (EIA standard available on request)
- Passband: 4 MHz
- Video signal input voltage: 1Vpp via 75 Ohm coax cable
or twisted pair.
Technical characteristics of Art. 6023
- Slim-line surface wall-mounted monitor with colour
screen 3,5".
- Minimum supply voltage: 15 Vdc (maximum 20 Vdc)
- Video signal standard: PAL
- Video signal input voltage: 1 Vpp via 75 Ohm coax
cable.
Fitting the monitor with interphone
Fig.1
Mount the bracket, part No. 6145, on the wall at a
height of approximately 1.40 m from the floor.
Fig.2, 3 Open the interphone, split the cover from the
bottom making pressure onthe lower side of the
cover
Fig.4
Inside the interphone, fit the connection card sup-
plied with the monitor Petrarca, and connect the
card to the interphone by means of connectors
CN2 (card) and CN1 (interphone).
Fig.5
Fit the base of the interphone on the left-hand
side of the bracket by inserting it into the appro-
priate seats and pulling it downwards until it locks
completely into position.
Make the connections to the terminals of the inter-
phone and the monitor card.
Fig.6
Connect the cabling of the monitor to the connec-
tion card by means of connector CN1 on the card.
Fit the monitor by positioning it in the appropriate
seats and pulling it downwards until it locks com-
pletely into position.
Fig.7
Close the interphone by fastening the casing to
the top of the base and press the bottom of the
casing until it clicks into place. To remove the in-
terphone or monitor from the bracket, press the
safety tab with a screwdriver and pull out in the
direction of the arrows.
EN
Installation of monitor and telephone
Fig. 8
Embed 3 module back box Art. 7149 so that it is
flush-mounted on the wall about 1.45 m from the
ground.
Fig. 9
Attach mounting bracket Art. 6146 using the 4
screws provided and keeping flush-mounted back
box at the right hand side of the plate. Fix the con-
necting circuit (provided with the monitor) on the
plastic seat provided with the plate.
Fig. 10 Carry out the connection of the installation to the
monitor connection circuit. Insert the telephone
cable (provided) in the connector in the socket
on the back of multi-function telephone Art. 3562.
Connect the other end of the cord to the tele-
phone line from the telephone switchboard (Art.
3528/N-3528) by inserting the plug in the socket
on accessory Art. 3560 (detail A).
Fig. 11 Attach the telephone to the mounting bracket by
hanging it over the hooks and pushing it down
until it is locked in place. Insert monitor cable in
the connector marked "CN1" on the connecting
circuit board (detail B). Finally mount the monitor
by hanging it over the hooks and pushing it down
until it is locked in place. To detach the telephone
or monitor from the mounting bracket, prise open
the safety tab with a screwdriver and detach the
unit by pushing it up (in the opposite direction to
that indicated by arrows 1 and 2).
N.B.:
Do not use the cable supplied with the connecting
circuit board.

INSTALLATION RULES

Installation should be carried out observing current installa-
tion regulations for electrical systems in the country where
the products are installed.
CONFORMITY
EMC directive
Standards EN 61000-6-1, EN 61000-6-3.
USER INFORMATION IN COMPLIANCE WITH
EUROPEAN DIRECTIVE 2002/96 (RAEE)
In order to avoid damage to the environment and hu-
man health as well as any administrative sanctions, any ap-
pliance marked with this symbol must be disposed of sepa-
rately from municipal waste, that is it must be reconsigned to
the dealer upon purchase of a new one. Appliances marked
with the crossed out wheelie bin symbol must be collected in
accordance with the instructions issued by the local authori-
ties responsible for waste disposal.
3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Elvox petrarca 6023