ENGLISH
8.3.
Connection to the mains (service technician)
The appliance may be connected to the mains
exclusively by the authorized and qualified
personnel and when the binding regulations are
observed and when the proper material is used in
accordance to the regulations.
The appliance is built to use the following power
(see the attached table):
380-415V 3N~ 50-60Hz
220-240V 3~ 50-60Hz
To prevent any risks the damanged supply
cable
may
manufacturer or expert.
The correct cross section of the cable is
presented in the attachments and should be
GB
decided by the electrician.
To correctly connect the appliance, follow the
following guidelines.
Remove the cover from term block (A).
Connect the switch-off to the term block (B) of
the appliance, as shown in the drawing and
block
diagram
Preferably use cable H07RN-F type or better,
which is resistant to high temperature min. up
to 80° C.
Tighten the cable endings (C).
Place the cover on the term.
8.4.
Installation of the appliance in a line
To fix the appliance in a line (neighbouring) follow
the steps:
1. Dismantle the control panel, and remove the
cast iron frame from the chimney if necessary.
2. Apply the sealing tape (A) onto the joining
sides.
be
exchanged
only
(see
the
attachment).
A
by
the
B
C
The appliance is equipped with the equipotential
clamp (M).
Respectively to the clamp used a special sticker is
envisaged:
M
3. Place the appliances next to each other and in
a horizontal position (by adjusting the feet).
4. Connect the appliances with the joining
elements.
5. Remove the excess of the sealant.
12