Grill (optional)
¡¡¡CAUTION!!! It is very important to turn off the timer (60 min) whenever you using the grill.
Humidifier (optional)
This option allows timely steam injection pressing the button 7 (see Table 1) and control manually
moisture during the cooking.
Changing single phase connection to three phase connection (mod. Rx-604, Rx 604
Plus, M 604 Plus)
1
Remove the back of the oven.
2
Disconnect the supply hose (5 x 2.5 mm2)
3
Connect the new hose (3 × 4 mm2) in the connection terminals as shown in the scheme above
4
Connect the bridges that are provided with this manual and connect as shown.
1
Remove the back of the oven.
2
Disconnect the supply hose (5 x 2.5 mm2)
3
Connect the new hose (4 x 2,5 mm2) in the connection terminals as shown in the scheme above
4
Connect the bridges that are provided with this manual and connect as shown.
Important: connecting cable in the oven (hose 5 wires x 2.5 mm2) should be replaced by another similar
characteristics or a larger cable (3-wire hose x 4 mm2).