3.4.3
Manual drain
The valve can be moved from "Filter" to "Drain". When the valve
reaches this position, the filter pump turns on. The "Drain" function
has no time limitation. In this operating mode the pool is drained.
During the draining process, the filter pump is supplied with power
internally.
NOTICE
Avoid running the pump dry.
3.4.4
Manual circulate
The valve turns to "Circulate" and the pump turns on. The eco
pump switches at n1. In this valve position, the water is circulated.
3.4.5
Manual closed
The valve turns to "Closed" and the pump does not turn on.
3.4.6
Manual filtering
The filter pump can be switched on manually in the filter position.
Speed n2 is output for speed-controlled pumps.
3.4.7
Off
No switching functions except for level control are executed in this
operation mode.
3.5
Outputs and inputs
3.5.1
Outputs
All relay outputs are potential-free changeover contacts. Phase L
must be wired to the appropriate common relay contact to switch
230 V.
3.5.2
Relay output z1-z2
The relay outputs are potential-free.
The contact z1-z2 is provided for other devices. If the contact z1-
z2 is closed, the external device acknowledges that the BADU
OmniTronic has reached its position and that the pump can be
turned on.
Factory settings:
Contact z1-z2 closes, when one of four positions is reached.
"P" may be selected additionally instead of "√" for the Filter
position. The "P" setting means that z1-z2 is closed if the pump is
04|2019
Description
EN 21