Connection and operation
Connection of electrode holder for MMA
The electrode holder and earth cable are
connected to plus connection (10) and minus
connection (8). Observe the instructions from the
electrode supplier when selecting polarity.
Adjustment of wire brake
The wire brake must ensure that the wire reel
brakes sufficiently before the welding wire runs
over the edge of the reel.
The brake force is dependent on the weight of
the wire reel and wire feed speed.
Factory setting is 15kg.
Adjustment:
• Dismount the control knob by placing a thin
screw driver behind the knob and thereafter
pull it out.
• Adjust the wire brake by fastening or
loosening the self-locking nut on the axle of
the wire hub.
• Remount the control knob.
Switch on, press, weld
Welding program setting
• Switch on the welding machine on the main
switch (2)
• Select welding program
welding wire and shielding gas or possible
electrode in use.
See program table
• Adjust the welding current and secondary
paramerers
The machine is now ready to weld
WARNING
Voltage is present on the welding
wire when pressing the welding
hose trigger.
10
Please read how this
should be selected
on your welding
machine in the quick
guide. Select the
welding program
suitable for the
Please read your quick-
guide
Various wire feed units
Use of MWF 41 Master and Slave
The slave unit is active and the green LED will
be turned on after a short pressure on the hose
trigger.
All settings are carried out on the master control
panel and will be automatically saved until the
slave unit is activated.
Please note that MWF 41 Slave and RWF have the
same functions.
Trolley with automatic mains voltage transition
(special equipment)
Machines supplied with autotransformer can be
connected to the following mains supplies:
3x230V, 3x400V, 3x440V og 3x500V.
Press the power switch (13) to turn on the
autotransformer (green indicator light). The
built-in energy saver function will automatically
turn off the welding machine after 40 minutes
of inactivity. Press the button (14) to turn on the
machine again (red indicator light).
The energy saver function can be permanently
disconnected by a Migatronic technician.
Software reading
• Insert the SIGMA SD-card in the slide in the
right side of the machine.
• Turn on the machine.
• The display flashes shortly with six lines.
• Wait until the set current is displayed.
• Turn off the machine and remove the SD card.
• The machine is now ready for use.
All connected wire feed units will be updated
with the new software.
It is necessary to read software inside the new
control unit by means of a SD card, if the control
unit has been exchanged.
The software can be downloaded from
http://migatronic.com/login
Use of MWF 41