Installation Instructions
C
Installing the Cooktop
Provide Adequate Gas
C1
Supply
This cooktop is designed to operate on natural
gas at 4" of water column pressure. It is
shipped from the factory set for natural gas
(except JGP319 models, which are set for LP).
The convertible pressure regulator supplied
with the unit must be connected in series with
the manifold of the cooktop and must remain
in series with the supply line regardless of
whether natural or L.P. gas is being used.
FOR PROPER OPERATION, THE MAXIMUM
INLET PRESSURE TO THE REGULATOR
MUST BE NO MORE THAN 14" OF WATER
COLUMN PRESSURE. For checking the
regulator, the inlet pressure must be at least
1" (or 3.4 KPA) greater than the regulator
output setting. If the regulator is set for 4" of
water column pressure, the inlet pressure
must be at least 5". If the regulator is set for
10", the inlet pressure must be at least 11".
The gas supply line to the cooktop should be
1/2" or 3/4" pipe.
Locate the electrical outlet
C2
and the Gas Shut Off valve
beneath the cabinet.
NEVER REUSE
OLD CONNECTORS
WHEN INSTALLING
THIS UNIT.
Install a manual shutoff valve in the gas line
in an easily accessible location outside the
cooktop. Be sure you know how and where to
shut off the gas supply to the cooktop. Install
the electrical outlet 12" below the countertop.
Shut Off
Electrical
Valve
Outlet
12" Below
Countertop
Installing the Regulator
C3
NEVER REUSE OLD CONNECTORS
WHEN INSTALLING THIS COOKTOP.
WARNING: Never reuse old flexible
connectors. The use of old flexible
connectors can cause gas leaks and
personal injury. Always use new
flexible connectors when installing
a gas appliance.
Screw a section of pipe
onto each end of the
pressure regulator.
To reduce the likelihood of gas leaks, apply
teflon tape or a thread compound approved
for use with LP or natural gases to all
threaded connections.
Install the regulator onto
C4
the burner box bottom
Screw the
regulator and
pipe connection
into the burner
box bottom.
Make sure the
top of the
regulator is
facing toward
the cabinet front,
easily accessible
through the
cabinet doors.
18
Pressure
Regulator
Pressure
Regulator
Shut Off
Electrical
Valve
Outlet
12" Below
Countertop