Instructions on fitting and installation
Warning
Before carrying out fitting, installation and mainten
ance work always switch off the power supply for the
electronic components.
Warning
If an axis is fitted in a sloping or vertical position, the
work load may fall down.
S Check whether external safety measures are necess
ary (e.g. toothed latches or moveable bolts).
S Use the motor unit preferably with self−locking
spindle drives.
You can then avoid the working mass sliding down if
there is a sudden power failure.
Warning
Use power supplies which guarantee reliable electrical
isolation of the operating voltage as per IEC/DIN EN
60204−1. Consider also the general requirements for
PELV circuits in accordance with IEC/DIN EN 60204−1.