Ec Declaration Of Conformity - Dustcontrol DC Tromb 400c Traducción Del Manual De Instrucciones De Servicio Original

Ocultar thumbs Ver también para DC Tromb 400c:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 29
Problem
Motor runs, but poor suction.
Machine blows dust.
Abnormal sound from machine.

EC Declaration of Conformity

We hereby declare that DC Tromb 400/a/c/L is in conformity with the following Directives and Standards: 2006/42/EC,
2014/35/EU, 2014/30/EU, EN 60204-1:2006/A1:2009, EN1822-1:A1:2009.
Dustcontrol AB
Anna-Lena Berg / CEO
2019-08-27
20
Cause
Suction hose perforated.
Blocked filter.
Suction hose too long or narrow.
Hose partially blocked.
Top of machine poorly fitted.
Dust trapped in cyclone.
Filter loose or damaged.
Peter Söderling / Technical Manager
DC Tromb, Art.nr. 9480-I
Action
Replace hose.
Clean or replace.
Replace hose.
Reverse or clean hose.
Adjust fitting.
Remove top and clean cyclone.
Check and replace as necessary.
Book service.

Publicidad

Tabla de contenido
loading

Tabla de contenido