Problem
Motor runs, but poor suction.
Machine blows dust.
Abnormal sound from machine.
EC Declaration of Conformity
We hereby declare that DC Tromb 400/a/c/L is in conformity with the following Directives and Standards: 2006/42/EC,
2014/35/EU, 2014/30/EU, EN 60204-1:2006/A1:2009, EN1822-1:A1:2009.
Dustcontrol AB
Anna-Lena Berg / CEO
2019-08-27
20
Cause
Suction hose perforated.
Blocked filter.
Suction hose too long or narrow.
Hose partially blocked.
Top of machine poorly fitted.
Dust trapped in cyclone.
Filter loose or damaged.
Peter Söderling / Technical Manager
DC Tromb, Art.nr. 9480-I
Action
Replace hose.
Clean or replace.
Replace hose.
Reverse or clean hose.
Adjust fitting.
Remove top and clean cyclone.
Check and replace as necessary.
Book service.