Anti-intrusion function test
[1]. Press button
to position the garage door in the low position.
[2]. Wait until the transmitter switches to sleep mode (instant if base magnet
installed).
[3]. Manually raise the door by pressing on the rubber.
The alarm is triggered.
[4]. Press a button on a remote control memorised in the receiver to stop the
alarm.
Optional: base magnet
4.2).

9 - ADVANCED PARAMETER SETTING

9.1 Different operating modes

> 2 operating modes are available:
Sequential (default mode)
Each press on the remote control causes the
motor to move (initial position: door closed)
as per the following cycle: open, stop, close,
stop, open, etc.
Semi-automatic
In semi-automatic mode:
- pressing a button on the remote control
during opening has no effect,
- pressing a button on the remote control
during closing causes it to reopen.
> 2 automatic closure options are available for the door:
Closure time delay
With automatic closure time delay:
- the door is closed automatically after the
programmed time delay has elapsed (20 s,
by default),
- pressing a button on the remote control
interrupts the movement taking place and
the closure time delay (the door remains
open).
Cell locking
After the door is opened, movement in front of
the cells (safe closure) will close the door after
If there is no movement in front of the cells,
the door will close automatically after the
programmed closure time delay (20 s, by
default).
If there is an obstacle in the cells' detection
zone, the door will not close. It will close once
the obstacle is removed.
Note: by default, no automatic closure option for the door is activated.
The installation of photoelectric cells is mandatory in the event that
an automatic closure option is activated.

9.2 Programming operating modes

> Changing the operating mode
mode to semi-automatic mode.
Indicator lights
M1
Copyright © 2014 Somfy SAS. All rights reserved.
Mode activated
M2
M3
Sequential
Semi-automatic

9.3 Automatic closing mode

> Activating automatic closure
Short press on the T button to activate automatic
closure.
Indicator light
> Modification of the automatic closure time delay
The automatic closure time delay can be adjusted from 5 seconds to 2 minutes
(20 seconds by default)
To modify the automatic closure time delay, one or other of the automatic
closure options must be activated.
[1]. Run the timer by pressing and holding down the T button for 2 seconds.
Indicator light
[2].
is obtained.
Indicator light
[1]
2s
5 s ... 2 min
[2]

9.4 Holiday mode

> Activating/deactivating holiday mode
The door must be closed to activate this mode.
To activate/deactivate holiday mode, press the
1
2
3
4
STOP
Prog
When holiday mode is active, each time a locked control (programming
interface or remote control) is pressed, indicator lights 1, 2, 3 and Prog start
> Holiday mode parameter setting
ON
OFF
X
(default
Dipswitch 5
setting)
Holiday mode
X
Automatic closure option
activated
Closure time delay
Cell locking
No option active
button until the 4 indicator
STOP
1
2
3
4
STOP
Prog
Comments
Programming Interface locked
(remote controls and keyswitch
active)
Remote controls locked (programming
interface and keyswitch active)