Clearing The Remote Controls; Clearing A Remote Control; Clearing All Remote Controls; Clearing Safety Edge Transmitters - SOMFY ROLLIXO RTS Manual De Instalación

Ocultar thumbs Ver también para ROLLIXO RTS:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Rollixo RTS

12 - CLEARING THE REMOTE CONTROLS

12.1 Clearing a remote control

Executing "Remote control memorisation" procedures on an already memorised
remote control clears it.

12.2 Clearing all remote controls

[1]. Press button
on the receiver (for approximately 7 seconds) until the
Prog
indicator light above it goes out.
[2]. Release button
on the receiver when the indicator light goes out; the
Prog
All memorised remote controls will be cleared.
Prog
Prog
Press and hold down for 7 seconds
13 - CLEARING SAFETY EDGE
TRANSMITTERS
Note: This operation must be carried out when a radio safety edge is replaced
with a wired safety edge.
[1]. Press button
on the receiver (for approximately 14 s) until the indicator
Prog
light above it goes out.
[2]. Release button
Prog
The safety edge transmitter is cleared.
Prog
Prog
Prog
Press and hold down for 14 seconds
14 - LOCKING/UNLOCKING THE
PROGRAMMING BUTTONS
The programming buttons must be locked to ensure user safety. When the
programming buttons are locked, the following functions cannot be accessed:
- entering programming mode by pressing button
- entering motor end limit setting mode by pressing buttons

receiver

- setting the operating modes.
To lock the programming buttons, press buttons
STOP
STOP
To lock the programming buttons, repeat the locking procedure described
above.
Copyright © 2014 Somfy SAS. All rights reserved.
Prog
Prog
Prog
Prog
Prog
Prog
on the receiver
Prog
and
and
on the receiver
Prog
STOP
1
2
3
4
Prog
1
2
3
4
Prog

15 - DIAGNOSTICS

15.1 Receiver
Indicator light status
Off
Permanently lit
Diagnostics
Fall
protection
Consequences
Actions
Diagnostics
Consequences
Actions
Diagnostics
Consequences
Actions
Diagnostics
Motor
Consequences
Actions
Diagnostics
Consequences
Actions
Diagnostics
Actions
on the
Diagnostics
Consequences
Optical wired
safety edge
Actions
Meaning
Functional installation
Waiting for an action/adjustment
Deactivation/activation in progress
Installation fault/failure
Indicator light status
Fall protection is not connected or there
is no bridge on the connector if fall
protection is connected to the shared
motor terminal
Fall protection triggered
No movement possible
Check the fall protection wiring (see
section 3.2).
Incorrectly wired motor
No movement possible
Check the motor wiring (see section 3.2).
Fall protection triggered (when fall
protection is connected to the shared
motor terminal)
No movement possible
Check the installation and replace the fall
protection.
Activated motor thermal protection
No movement possible
Wait around 10 minutes.
Faulty motor or fuse blown
No movement possible and integrated
lighting off
Check the condition of the fuse and
replace it if necessary (spare fuse
supplied, see section 2.2, point 13).
If the motor still does not work, replace it.
Waiting for motor adjustment
Set the motor end limits (see section 3.4).
Optical wired safety edge failure
Opening ok
Closing by pressing and holding down
the button within sight of the door
- Check the type of safety edge connected
(optical wired safety edge, dipswitch
no.4 set to OFF); if the connected wired
safety edge is resistive, move dipswitch
no.4 to ON.
- Check the safety edge wiring (see
section 8.3).
- Check that no radio safety edge
transmitter is stored in the receiver. If a
radio safety edge transmitter is stored in
the receiver, clear it (see section 13).
Prog
13

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido