WARNING
• Install the equipment by carefully following the instructions given by the manufacturer and in compliance with the legislation in force.
• All the equipment must only be used for the purpose it was designed for. Comelit Group S.p.A. does not assume responsibility for improper
use of the appliances, for modifications made by others for any reason or purpose, or for non-original accessories and materials.
• All products comply with the requirements of the 2006/95/CE directives (which replace the 73/23/CEE directives and subsequent amendments), as certified by
the CE mark on the products.
• Do not route the riser wires in proximity to power supply cables (230/400V).
GENERAL INFORMATION
The Single-family Art. 8471 and Two-family Art. 8472 Door Entry Telephone Kits
can be used in civilian or service buildings in which efficient access control is
required, with simple installation operations.
In effect it only requires 2 wires between the external unit and the internal
monitor/s to activate the system (calls, intercom, video automatic light up), plus
two wires to provide the 12V AC power supply the external unit electric lock.
A wide range of accessories is also available (Genius-Kit catalogue 105) to deal
with the needs of any type of system. As well as interesting standard type
accessories, it is also possible to extend the system, adding Video entry phones
and/or Phones and/or external units.
In this way it is possible to reach a maximum of two external units with three
internal units (made up of Telephones and Entry Telephones) for the single-
family configuration, and two external units with six internal units (made up of
Telephones and Entry Telephones - three call Buttons) for the two-family
configuration.
INTERNAL UNITS
Art. 5801
1 3-position call tone selector
Left position: Maximum call tone volume
Central position: Medium call tone volume
Right position: Low call tone volume
2 Door-opening pushbutton
3 Monitor handset
(Lift the handset to start communication)
4 Pushbutton 1 available as standard for actuator function
5 Pushbutton 2 available as standard for Automatic switch-on/Video request
6 4" Black and white screen
7 Brightness adjustment knob (turn clockwise to increase brightness).
Art. 1205/B
Specifications
The transformer provides 2 outputs: one to supply the external unit and the
electric lock, the other to supply the monitor.
Dimensions: 105x85x85 mm.
500mA delayed protection fuse.
Description of the terminal board
AC230V network voltage input
~~ AC output for external unit and electric lock
+ - 20V DC power supply output of the monitor
Art. 5814K
1. Bracket-monitor connector.
2. System connection terminals:
0V 20V terminals for connection to Art. 1205/B or Art. 1212/B.
L L Bus line connection terminals.
CFP CFP local floor call input.
P1 C1 Pushbutton for various usages. To have a clean C.NO. contact,
remove jumpers CV3 and CV4 (max 24V - 100mA).
S+ S- Terminals for call repeater device.
3. User address programming jumper.
4. Jumper CV5 to close the video signal.
5. Jumpers CV3 and CV4 (remove to have a clean C.NO. contact on terminals
P1C1).
6. Jumper JP1. Used to set the Monitor bracket as Main or Secondary. (See
page 7)
MT KIT 08
11
MT KIT 08