1.0 - GENERAL
This manual shows you how to safely install, operate and use the device.
The instructions for use ALWAYS need to be available in the facility where the device is installed.
ATTENTION: installation/wiring/maintenance need to be carried out by qualified staff (as explained
in section 1.3) using appropriate personal protective equipment (PPE).
For any information pertaining to installation/wiring/maintenance or in any case problems that cannot be resolved with the use
of the instructions, it is possible to contact the manufacturer from the address and phone numbers provided on the last page.
1.1 - DESCRIPTION
Normally closed, manual reset solenoid valves for gas, suitable to shut-off gas and signal danger sent by gas detectors (methane,
LPG, carbon monoxide and similar) or safety thermostats, and for blackouts.
For additional safety, this solenoid valve can only be reset with the power supply connected and only when the gas detector
is not signalling danger.
IMPORTANT NOTE: The valve will not open by simply powering the coil. You must manually press the reset
mechanism (as indicated in 4.0).
They can be equipped with CPI switches to control the valve's plunger position (open or closed) from remote.
The CPI can also be installed at a later stage. Further information regarding the CPI switch is available in 7.0.
Reference standards: EN 161 - EN 13611.
1.2 - KEY OF SYMBOLS
DANGER: In the event
of inobservance, may
be caused damages to
tangible goods.
1.3 - QUALIFIED STAFF
These are people who:
• Are familiar with product installation, assembly, start-up and maintenance;
• Know the regulations in force in the region or country pertaining to installation and safety;
• Are trained in first aid.
1.4 - USING NON-ORIGINAL SPARE PARTS
• To perform maintenance or change parts (ex. coil, connector, etc.) ONLY manufacturer-recommended parts can be used.
Using different parts not only voids the product warranty, it could compromise correct device operation.
• The manufacturer is not liable for malfunctions caused by unauthorised tampering or use of non-original parts.
1.5 - IMPROPER USE
• The product must only be used for the purpose it was built for.
• It is not allowed to use different fluids than those expressly stated.
• The technical data set forth on the rating plate must not be exceeded whatsoever. The end user or installer is in charge of
implementing proper systems to protect the device, which prevent exceeding the maximum pressure indicated on the plate.
• The manufacturer is not responsible to damage caused by improper use of the device.
M16/RM N.C. EEX
DANGER:
In
the
inobservance, may be caused damages
to tangible goods, to people and/or pets.
10
event
of
ATTENTION: Attention
is drawn to the technical
details
qualified staff.
Madas Technical Manual - REV. 0 of 10
intended
for
May 2018
th