JAZZ GB2 VIDEO DOOR ENTRY SYSTEM KIT - HOUSE
SAFETY PRECAUTIONS
- Always disconnect the power supply
before installing or making modifications to the devices.
-
The fitting and handling of these devices must be carried out by authorised personnel.
The wiring must run at least 40 cm away from any other wiring.
-
-
On the power supply unit:
Do not overtighten the screws on the connector.
w
Install the power supply unit in a dry protected location free from the risk of dripping or splashing
w
water.
wAvoid locations that are humid, dusty or near heat sources.
wEnsure that the air vents are free from obstruction so that air can circulate freely.
wTo avoid damage, the power supply unit must be firmly secured in place.
wTo prevent electric shock, do not remove the cover or handle the wires connected to the terminals.
( )
CHARACTERISTICS
*
-
Video door entry system with simplified wiring (non-polarised 2-wire bus).
-
Up to 4 access panels (DP-GB2A distributor required for more than one access panel) per
installation.
-
Up to 2 apartments per installation.
-
Maximum 6 Vesta2 monitors or 4 Vesta7 monitors per installation.
-
Maximum 4 monitors in parallel (without distributors) per installation.
-
In installations with 1 apartment, maximum 6 Vesta2 monitors or 4 Vesta7 monitors.
-
In installations with 2 apartments, maximum 6 Vesta2 monitors or 4 Vesta7 monitors.
-
Combinations with Vesta2 monitors:
monitor in one apartment and 5 monitors in the other apartment.
w1
monitors in each apartment.
w3
-
Combinations with Vesta7 monitors:
monitor in one apartment and 3 monitors in the other apartment.
w1
monitors in each apartment.
w2
-
Confirmation tone when the call button is pressed.
SYSTEM OPERATION
-
To make a call, the visitor must press the button of the apartment; an audible sound indicates that
the call is being made and LED
will turn on. At this moment, the apartment's monitors receive
the call. If another apartment is called by mistake, press the button for the correct apartment and
the first call will be cancelled.
-
In systems with several access doors, the other door panel(s) will be automatically disconnected.
If another visitor tries to call, a number of telephone tones will be heard to indicate that the system
is busy and LED
will illuminate.
-
The call lasts for 40 seconds. The image appears on the monitor (with code 0 'apartment 1' or
code 16 if the call is in 'apartment 2') when receiving the call without the visitor knowing.
If the call is not answered within 40 seconds, LED
-
To establish communication, press button
will turn on. If the monitor is a VESTA2 GB2/H or VESTA7 GB2/H with icon
make sure that the hearing aid is between 15 and 25 cm away from the monitor to ensure
maximum audio quality during communication with the door panel.
-
Communication will last for one and a half minutes or until button
communication has finished, LEDs
and will turn off and the channel will be freed.
-
To open the door, press button
during the call or communication processes: one press will
activate the lock release for five seconds and LED
-
For a description of the functioning and setup of the monitor, see the monitor's user manual.
( )
For more information, see the TJAZZ VESTA2-VESTA7 user manual (code
*
https://doc.golmar.es/search/manual/50122156
will turn off and the channel will be freed.
on any monitor in the apartment. Door panel LED
on the front,
is pressed again. When
will also turn on for five seconds.
50122156).
2
JAZZ GB2 VIDEO DOOR ENTRY SYSTEM KIT - HOUSE
INSTALLATION OF THE DOOR PANEL
( )
*
Location of the door panel:
Locate the top of the door panel at a height of 1.65m.
Wiring the door panel:
To a c c e s s t h e c o n n e c t i o n
terminals, remove the nameplate
label.
( )
*
Description of the door panel illumination LEDs (for low light conditions).
( )
*
Description of the visual signals on the door panel.
( )
*
Configuring call/door panel mode with or without shield.
( )
*
Configuring the contact type for lock release and auxiliary device output.
( )
*
Configuring card reader illumination mode/LED function mode (low light conditions).
Setting the door panel communication volume.
If the audio volume of the door panel is too low after turning it on, follow these steps:
-
Call the apartment.
-When the call is received in the apartment, establish communication by pressing button
the monitor.
-
Then press the button used to call the apartment for 3 seconds until a number of confirmation
tones are heard and door panel communication LED
-
Each press on the call button will increase the door panel volume and blink speed of the LED.
There are 5 volume settings and the blink speed of LED
blink - low to high volume. After reaching setting 5, maximum blink speed and volume, the next
setting is 1, minimum blink speed and volume (carousel mode).
-
To save the volume setting, keep the button pressed until a number of confirmation tones are
heard and the door panel communication LED turns on.
( )
*
For more information, see the TJAZZ VESTA2-VESTA7 user manual (code 50122156).
https://doc.golmar.es/search/manual/50122156
1850
1650
1450
Then connect the wiring to the connector
strip of the electronic module, following
the instructions in the wiring diagrams.
starts to blink.
will increase for each. Slow to fast
3
AP+
AP- C1 NA1
CV-
CV+
BUSBUS
on