ART 7H/G2+ MONITOR
SAFETY PRECAUTIONS
-
Always disconnect the power supply
before installing or making modifications to the device.
- The fitting and handling of these devices must be carried out by
- The wiring must run at least 40 cm. away from any other wiring.
- Do not overtighten the screws on the connector.
- Install the monitor in a dry protected location free from the risk of dripping or splashing water.
- Do not place in humid, dusty or smoky locations, or near sources of heat.
- Before connecting the device to the mains, check the connections between the door panel, power
supply, distributors and monitors.
-
Always follow the instructions contained in this manual.
( )
CHARACTERISTICS
*
-
Hands-free monitor.
- 7" TFT colour screen.
- The monitor ART 7H/G2+, interacts with hearing aids equipped with T-mode, making conversation
between apartment and door panel easier.
-
Push buttons/ hidden push buttons
for access and selection of menu function.
- Monitor with simple installation (non-polarised 2 wires bus).
- User menu.
- Installer menu.
- Image and communication settings menu.
- Output auxiliary call repeater (max.50mA/12Vdc).
-
"HZ" input for calls from apartment front door
- Push button for Door release 1 and hidden push button for Door release 2.
-
Notification l
eds.
-
Configuration switches to assign the
call
address
- Function codes to define whether the monitor is master or slave (default: master).
( )
SYSTEM OPERATION
*
-
To make a call, the visitor must press the button of the apartment; an audible sound indicates that the
call is being made and
the door panel
LED
progress' message appears indicating that a call is being made. At this moment, the apartment's
monitors receive the call. If another apartment is called by mistake, press the button for the correct
apartment and the first call will be cancelled.
- Upon receiving the call, the image will appear on the screen of the master monitor (and slave 1, if it exists)
without the visitor knowing and icon
displayed on the screen will blink green. To view the image from
slave monitors 2 or 3, press the one of the buttons (located above the raised dots for the visually
impaired) of the monitor to display
the image. If the call is not answered within 45 seconds,
panel LED
will turn off and the system will become free.
- To establish communication, press
the push button below
Door panel LED
will turn off and the led
the hearing aid is between 15 and 25 cm away from the monitor to ensure maximum audio quality
during communication with the door panel.
- Connection will last for 90 seconds or until
the push button below
screen is pressed
. When communication ends,
become free. If vocal synthesis is enabled, a 'Communication is finished' message will indicate that
the call is over.
-
To open door
or
of the door panel
, press the
1
2
or press the hidden push button below of icon
communication processes: one press will activate the lock release for
LED
will also turn on for
3
seconds. If vocal synthesis is enabled, a 'Door
indicated on the door panel.
- Detailed operation
and configuration
of the monitor
( )
INSTALA
TION OF THE
MONITOR
*
( ) For more information, see
( )
*
"TART 7 /G2+
H
https://doc.golmar.es/search/manual/50122464
authorised personnel
.
.
(1 to 128)
and
end of line.
will turn on. If vocal synthesis is enabled, a 'Call is in
off-the-hook icon
shown
on the screen.
will
turn on
.
If you have a hearing aid make sure that
,
on-the-hook icon
shown on the
door panel
LED
will turn off and the system will
push button below of
icon
displayed on the screen
1
displayed on the screen during the call or
2
3
seconds and
the door panel
is
open' message will be
, see "TART H/G2+"
7
monitor
user manual
user manual
(cód. 50122464)".
2
ART 7H/G2+ MONITOR
( )
DESCRIP
TION
*
A
B
C
D
I
J
K
I
( )
Monitor address (code) setup:
*
Dip1 Dip7:
-
Sets the monitor address (addresses to
The switches set to OFF have a zero value. The values of the switches set to ON are shown in the table below. The
monitor code is the sum of the values of the switches set to ON.
Important: Apartment 1 (Dip1 to ON & Dip2-Dip to OFF).
Important: Apartment 2 (Dip1 - Dip to OFF).
Dip8: This activates the end-of-line resistance in the ON position. Activate it in monitors where the bus cable ends.
Deactivate it only in intermediate monitors.
Dip 8
to
ON
the door
ON
1
2
3
4
5
6
7
Not : e To define whether the monitor is master or slave, entering the corresponding "Special code":
"0550" Master (factory default),
Dip1 to Dip : 7 These assign the address of the monitor to call button on the door panel.
Switches - must remain in the OFF position.
4 7
Apartment 1
ON
1
2
3
4
5
6
7
Dip8: This activates the end-of-line resistance in the ON position. Activate it in monitor where the bus cable ends.
Deactivate it only in intermediate monitors.
Dip 8 to ON
ON
1
2
3
4
5
6
7
.
Not : e
To define whether the monitor is master or slave, e
"0550" Master (factory default),
( )
*
For more information, see
https://doc.golmar.es/search/manual/50122464
EN
MONITOR
A. Speaker.
B. Notifications icons:
Power on indicator.
Do not disturb.
Auxiliary relay activated.
C. Hidden push button indicator Leds
To access the main menu (monitor in standby), press either
of the 2 buttons
E
visually impaired (see "TART 7 /G2+" manual).
In call/ communication: press button to start or end the
communication.
In call/ communication: one press will activate the lock
release 1 for 3 seconds.
F
In call/ communication a LED shows the location of each
*
of the hidden buttons.
G
T
he function of each
H
monitor screen with an icon located just above each
Hidden button
button see "TART 7 /G2+" manual
(
pressing area
D. Raised dots for the visually impaired.
In standby:
Above the raised dots for the visually impaired
the buttons that access the main menu.
12210702
V01
MONITOR 7" ART 7H/G2+
I
128
In call:
codes
GOLMAR S.A.
CAUTION
C/ Silici, 13
08940 - SPAIN
TO PREVENT ELECTRIC SHOCK,
WARNING
DO NOT REMOVE COVER.
Above this raised dot is the Start End
TO PREVENT FIRE OR ELECTRIC
NO USER SERVICEABLE PARTS
SHOCK, DO NOT EXPOSE THIS
INSIDE. REFER SERVICING TO
DEVICE TO RAIN OR MOISTURE
QUALIFIED SERVICE PERSONNEL
button
ON
1
2
3
4
5
6
7
8
Above this raised dot is the Door opening
SA
K
GND
E.
7"
TFT colour screen.
HZ
HZ
F.
Micro SD card slot (not included).Type:MicroSD Class 10
SA
128
BUS
from 4Gb to 128Gb.
DIP 1 to 7
codes
Monitor address
IN
GND
I
HZ
DIP 8
BUS
OFF = 0
G. Micr
ophone
EOL resistor
OUT
HZ
ON = 1
H. Communication with hearing aids
Set the hearing aid switch to the T position.
I.
Wall mounting connector fixing (x4).
J. Configuration switches.
K. Installation terminals.
Building / Villa (Nexa Door Panel)
1
1 8
2
).
Table of values
7
Switch number:
1 2 3 4 5
1 8
7
Value when ON
:1 2 4 8 16 32 64
Dip 8
to
OFF
ON
8
1
2
3
4
5
6
7
8
"0551" Slave
1,
"0552" Slave or "0553" Slave .
2
Villa (Soul Door Panel)
*
Apartment 2
Apartment 3
ON
ON
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Dip 8 to OFF
ON
8
1
2
3
4
5
6
7
8
ntering the corresponding "Special code"
"0551" Slave
1,
"0552" Slave or "0553" Slave .
2
"TART 7 /G2+
H
user manual
(cód. 50122464)".
3
Door opening
. 1
New image/video.
*
:
/
located above the raised dots for the
H
:
button/
hidden button is shown on the
H
).
/
are
"
/
com unica
m
tion
"
.
"
1"
button
.
.
(
ART H G2+
7 /
monitor)
.
ON
6
7
1
2
3
4
5
6
7
8
Example: 0+ 0+4+0+ 16+
0+0
= 20
3
*
Apartment 4
ON
Kit Soul / Art 7H
1
2
3
4
5
6
7
8
manual
:
3
EN