Technical Data; Power Requirements - Truper PISCA-A Manual Del Usario

Ocultar thumbs Ver también para PISCA-A:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Technical Data

Code
Description
Voltage
Frequency
Current
Power
Speed
Work Cycle
Conductors
Insulation
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
WARNING

Power Requirements

WARNING
If faults or breakdowns happen. Ground connection offers a
trajectory with minimum resistance for electric power. It reduces the risk of electric
shock. This tool is built with a power cable with an earth conductor and a plug with
ground connection. The plug shall be connected into a power outlet installed and
grounded according to all local codes.
WARNING
Do not modify the plug supplied. If the plug cannot be fitted
to the socket, have a qualified electrician to install the suitable socket.
Ampere
Capacity
from 0 A and up to 10 A
from 10 A and up to 13 A
from 13 A and up to 15 A
from 15 A and up to 20 A
WARNING
When operating power tools outdoors, use a
extension cable labeled "For Outdoors Use". These extensions are specially designed for
operating outdoors and reduce the risk of electric shock.
There is risk of fire if the tool is not used with care, so it is necessary to:
WARNNG
Be careful when using the tool in places where combustible materials are present. Do not apply in the same place for
prolonged periods. Do not use in the presence of explosive atmospheres. Keep in mind that some combustible materials can lead to heat
without this being evident in sight. Place the tool in its base after it is used and allow it to cool down before it is stored. Do not leave the tool
unattended when it is in operation.
30 minutes work per 15 minutes rest. Maximum 3 hours daily.
14 AWG x 3C with insulating temperature of 221 °F
Number of
Conductors
3 (one grounded)
* It is safe to use only if the extensions have a built-in artifact for over current protection.
AWG = American Wire Gauge. Reference: NMX-J-195-ANCE-2006
PISCA-A
16432
Heat Gun
127 V
60 Hz
16 A
2 000 W
11 000 RPM - 17 000 RPM
Class I
Power Cord Grips used in this product: Type Y.
Tool Build Quality: Basic Insulation.
Authorized Service Center.
Extension gauge
from 6 ft to 49 ft
18 AWG( * )
16 AWG
14 AWG
8 AWG
grounded
|
higher than 49 ft
16 AWG
14 AWG
12 AWG
6 AWG
ENGLISH
3