Blink codes failure indicator lamp
Signal
Lamp does not light up
when the ignition has
been switched on
Lamp does light up 5
seconds after the igni-
tion is switched on for
3 seconds
Lamp continously lit
for 2 minutes at the
end of the pumping
phase.
Attention:
If the cause of the
lamp indicator cannot
be remedied by you,
take then immediate
contact with your sup-
plier or with Groen-
eveld Transport
Efficiency.
Lamp blinks with a fre-
quency of 1 x 0,3 s on /
2,0 s off.
Lamp blinks with a fre-
quency of 2 x 0,3 s on /
2,0 s off.
Lamp blinks with a fre-
quency of 3 x 0,3 s on /
2,0 s off.
XU1601D
Cause/Meaning
1 The TriPlus system is not powered. Check fuses
and connections to earth. Immediate action
required!
2 Lamp or wiring to lamp defective. Check lamp
and wiring and replace if necessary.
The TriPlus system is powered and the control
lamp is OK.
During the pumping phase a failure has
occured.
Possible causes:
- The pump does not function properly.
- Reservoir empty. The reservoir must be
refilled.
A test cycle via outlet 1 of the pump is carried
out.
A test cycle via outlet 2 of the pump is carried
out.
A test cycle via outlet 3 of the pump is carried
out.
7