INSTALLATION

RECOMMENDED INSTALLATION

The figure below shows the recommended configuration for the installation
of a diaphragm pump.
AIR EXHAUST DISPOSAL
WARNING
• Optional kit is required for remote exhaust.
• Unscrew the 4 bolts and remove the standard muffler (pos. 1-10, pos.
1-12) in pump part drawing page 8.
• Place the remote exhaust adaptor (pos. 1-41), (remember to install the
included o-ring on its housing, (1-40). Screw the four bolts (pos. 1-42)
previously removed.
• Connect a hose to the new exhaust port and install the muffler at the end
of the hose. Use a hose with the same diameter as the exhaust port 3/4"
NPT. (If the hose is more than 5 feet (1.5 m), consult your dealer or Balcrank).
• Have a moat, a protective housing, etc. at the end of the hose.

AIR CONNECTION

WARNING
To ensure that the air supply is sufficient to meet the demand of the pump,
the diameter of the pipe must be equal to the diameter of the supply port of
the pump. Choose auxiliary air treatment equipment and fittings with
sufficient airflow to exceed the air consumption of the pump. In addition,
Balcrank Corporation • Weaverville, N.C. 28787 • Phone (800) 747-5300 • Fax (800) 763-0840
Read the warnings and recommendations of the previous page before
starting.
Note: To use the top pump
connection, remove the plug and
install the outle hose using a
connector compatible with pump
threads. Use the plug to close the
standard pump outlet. Use Teflon
tape to seal the new plug
placement.
peripheral air treatment equipment must be installed as close as possible to
the pump unit.
The use of a coupler to connect the hoses aids future operation and
maintenance tasks.