INSTALLATION
TF170 PUMPS ARE VERY EASILY CONFIGURED AND EASY TO INSTALL
FLOODED:
The pumping system was designed with positive pressure at the inlet.
This is the best possible installation when you need to evacuate the liquid
from the drum or tank, or when working with viscous fluids.
Not recommended for hazardous fluids.
SELF-PRIMING:
Pump is designed to generate vacuum. It is possible to evacuate all the
air from a hose or pipe without damaging the pump. Maximum suction
height is (6 m) 19.69 ft, with the suction hose empty and up to 8 m (26.25
ft) with the hose primed.
FLOODED

RECOMMENDED INSTALLATION

The figure below shows the recommended configuration for the installation of a diaphragm pump.
Read the warnings and recommendations of the previous page before starting.
METALLIC
>=2"
FLUID
INLET
SELF-PRIMING
NOTE: Use a pressure regulator with built-in filter inlet.
NOTE: The compressed air supply must be between 1,5 bar (22 psi ) and 8 bar (115 psi).
2"
OPTION
SUCTION
DRAINING
VALVE
 Balcrank Corporation - Weaverville - NC · Tel.: 800-747-5300 · www.balcrank.com
SUBMERGED:
All pumps can be immersed in fluids. It is important to verify that all
components that are in contact with the fluid are chemically compatible.
In this case, air exhaust and fluid must be carried by hoses (optional air
connection).
DISCHARGE
DRAINING
VALVE
OUTLET
OPTION
>=2"
2"
3/4"
MAX. 8 bar
3/4"
OPTION
SUBMERGED
R. 06/20 SB 1206
EN
EN
5