Dell PowerEdge M1000e Procedimientos Iniciales Con El Sistema página 23

Ocultar thumbs Ver también para PowerEdge M1000e:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 158
Environmental (continued)
Relative humidity
Operating
Storage
Maximum vibration
Operating
Storage
Maximum shock
Operating
Storage
Altitude
Operating
Storage
Airborne Contaminant Level
Class
I/O Module Specifications
For information about the I/O modules and pass-through modules supported
on your enclosure, see the Dell PowerEdge M1000e Systems Configuration
Guide at support.dell.com/manuals.
20% to 80% (noncondensing) at a maximum wet bulb
temperature of 29 °C (84.2 °F)
5% to 95% (noncondensing) at a maximum wet bulb
temperature of 38 °C (100.4 °F)
0.26 Grms at 10 Hz–350 Hz for 15 min
1.54 Grms at 10 Hz–250 Hz for 15 min
One shock pulse in the positive z axis (one pulse
on each side of the system) of 41 G for up to 2 ms
Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse
on each side of the system) of 71 G for up to 2 ms
–15.2 m to 3,048 m (–50 ft to 10,000 ft)
–15.2 m to 10,600 m (–50 ft to 35,000 ft)
G1 as defined by ISA-S71.04-1985
Getting Started With Your System
21

Publicidad

Tabla de contenido
loading

Tabla de contenido