Operating instructions
UE3212
Note
8010726/TF84/2010-07-20
Subject to change without notice
Technical specifications
Socket I1/2
Wiring
Voltage supply
Short-circuit detection
Cross circuit detection
Output current at L+
Input current at I1 (p)
Input current at I2 (n)
Opening time for the contacts
Cable length
Surroundings
Operating temperature
Storage temperature
Air humidity (non6condensing)
Rigidity
Shock resistance
8.2

Response times

The response time corresponds to the propagation time in the safe bus node UE3212; this
is the maximum time required, i.e. also in case of a fault, between the shut down of the
sensor outputs and the availability in the AS6Interface chip in the safe bus node.
To calculate the safety distance for a protective device you must take into account:
the response time of the switching contacts connected to the safe bus node UE3212
the response time of the safe bus node UE3212
the response time of the safety monitor
the stopping time of the machine or system
Information on the response times of the corresponding devices can be found in the
related operating instructions.
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Minimum
Typical
DC PNP/NPN
Via AS-i
Yes
<20 Ohm
170 mA
43 ms
–25 °C
–30 °C
5 g, 55...150 Hz (EN 60 0686266)
30 g, 18 ms (EN 60 06862627)
GB
Chapter 8
Maximum
12 mA
12 mA
5 m
65 °C
85 °C
93 % at 40 °C
99