Technical Data; Power Requirements - Truper SME-10X-3 Manual Del Usuario

Ocultar thumbs Ver también para SME-10X-3:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Technical Data

Code
Description
Measurements
Disc
Motor
Speed
Voltage
Frequency
Current
Work Cycle
Conductors
Insulation
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
WARNING

Power Requirements

WARNING
The tool shall be grounded while in use to prevent an electric shock!
The saw shall be I stalled as close as possible of the main power supply. Check the power supply is the same voltage indicated in
the motor nameplate.
WARNING
This device shall be grounded!
CAUTION
The power cables are codified with the following colors:
WARNING
When using an extension cable, double check it is the gauge enough to transport the current the tool
will need. A lower caliber cable will cause voltage drops in the line, resulting in power loss and overheating of the motor.
The following table shows the right gauge to use depending on the cable length and the ampere capacity indicated in the
tool nameplate. When in doubt, use the next higher gauge.
Ampere
Capacity
From 0 and up to 10 A
From 10 and up to 13 A
From 13 and up to 15 A
From 15 and up to 20 A
120 min work per 30 min rest. Daily Maximum 6 hours.
14 AWG x 3C with 221 °F Insulation Power
Class I
Power cord grips used in this product: Type "Y".
Thermal insulation on motor winding: Class H
Number of
Conductors
3 (one grounded)
* Allowed to be used only if the extensions have a built-in overcurrent protection device.
AWG= American Wire Gauge. Reference: NMX-J-195-ANCE-2006
SME-10X-3
10640
Table Saw with Extension
82" x 41" x 34" Base: 20" x 20"
10"
3 Hp
3 450 RPM
220 V
60 Hz
12,8 A
IP Grade
Build quality: Reinforced Insulation
Authorized Service Center.
Extension Gauge
From 6 ft to 49 ft
18 AWG
16 AWG
14 AWG
8 AWG
IP20
GREEN
GROUND
WHITE
LINE 1
BLACK
LINE 2
|
Higher than 49 ft
16 AWG
14 AWG
12 AWG
6 AWG
ENGLISH
3

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Tabla de contenido