Electrical Connection; Before Calling Service; Product Data Plate - Thermador CEM Instructions De Securite Importantes

Ocultar thumbs Ver también para CEM:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Electrical Connection

Before Calling Service

Product Data Plate

Figure 6 - Secure Cooktop to Countertop
burner box
bracket
adjusting screw
1. Attach flexible conduit to the junction box.
2. Connect the cooktop lead wires to the junction box supply wires in proper
phase. For all models, connect black (L1) to black, red (L2) to red, green
wire to ground.
NOTE: If the cooktop is installed and connected as specified above, it will be completely
grounded in compliance with the National Electrical Code.
3. Remove everything from the cooktop surface and apply Cooktop Cleaning
Creme (packaged with cooktop) as directed in Use and Care Manual.
4. Turn on power supply.
5. Test operation.
CAUTION:
Your cooktop surface needs to be cleaned daily. Refer to the Use and
Care section before using it for the first time.
If the elements do not heat or if the indicator "on" light does not glow, check the
power source to see if a fuse has blown or if the circuit breaker has tripped.
Refer to the Warranty in the Use and Care Manual. See Use and Care Manual for
troubleshooting information.
The data plate shows the model and serial number of your cooktop. It is located in
the center front area of the rough-in box, underneath the cooktop.
Keep your invoice or escrow papers for warranty validation if service is needed.
wood block
English 5

Publicidad

Tabla de contenido
loading

Tabla de contenido