Replacing The Batteries; Care And Maintenance; Technical Data - Stabila LAR-200 Instrucciones

Ocultar thumbs Ver también para LAR-200:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Replacing the batteries

Unfasten the catch on
1.
the battery compartment
cover: remove the cover
and the batteries. Insert
new batteries following
the instructions in the
battery compartment.
Only use 1.5V mono cells
(size D) !
Or use rechargeables.
Mono, D , LR20
Tip:
Remove the batteries if the unit will not be used for a long period !
Operating status display and error messages
Illuminated g g r r e e e e n n LED
-> laser in operation
Illuminated g g r r e e e e n n LED +
-> The laser levels itself automatically
laser beam f f l l a a s s h h i i n n g g
F F l l a a s s h h i i n n g g g g r r e e e e n n LED
-> The unit is inclined too much
+ laser beam f f l l a a s s h h i i n n g g
+ is outside the self-levelling range
+ the laser cannot level itself automatically
Illuminated r r e e d d LED
-> laser in operation
-> battery voltage very low
-> battery replacement required imminently
Illuminated r r e e d d LED
-> The laser levels itself automatically
+ laser beam f f l l a a s s h h i i n n g g
-> Battery voltage very low
-> Battery replacement required imminently
F F l l a a s s h h i i n n g g r r e e d d LED
-> Battery voltage very low
-> The unit is inclined too much
+ laser beam f f l l a a s s h h i i n n g g
+ is outside the self-leveling range
+ the laser cannot level itself automatically
2.
7
via the LEDs
6

Care and maintenance

• Dirty lens glass on the beam emitter detracts from the quality of the beam.
It should be cleaned with a soft cloth.
• Clean the laser unit with a damp cloth. Do not spray or immerse the unit!
Do not use solvents or thinners!
The LAR-200 rotation laser must be handled carefully, in the same way as any
precision optical instrument.

Technical data

Laser type:
Red diode laser, wavelength 650 nm
Output:
< 5 mW, Laser Class IIIa
This product complies with the applicable
requirements of 21CFR parts 1040.10 and 1040.11.
Self-leveling range:
ca. ± 5°
Leveling accuracy:
± 0,1 mm/m or ± 1/8" over 100 ft
Batteries:
2 x 1,5 V Mono cells Alkaline, Size D, LR20
Operating life:
Approx. 120 hours
Operating temperature range:
-10°C to +60°C or 14°F to +140°F
Storage temperature range:
-20 °C to +70 °C or -4°F to +158°F
Subject to technical modifications.
Guarantee terms and conditions
Stabila provides a guarantee against deficiencies and faults in the assured characte-
ristics because of material or manufacturing faults for a period of 24 months from
date of purchase. Any faults will be eliminated at Stabila's own discretion either by
repairing or replacing the unit. Stabila accepts no wider claims.
No liability is accepted for any faults due to inappropriate treatment (e.g. damage
caused by the unit falling, operation with the wrong voltage or type of current, use of
unsuitable current supply sources) or for any autonomous changes made to the unit
by the purchaser or a third party.
Also no claims under guarantee are accepted for natural wear and tear or any small
faults that do not significantly affect the unit's operation.
Any guarantee claims must be made via the dealer on the duly completed guarantee
form (see last page) to be returned with the unit.