Weekly Care And Cleaning
Disinfecting Directions - Disinfect Following Scale Removal
Step 1
Step 2
1. Add 1 Teaspoon of bleach to 1 gallon (3.8L) water.
2. Add ½ to ¾ gallon (1.9L-2.8L)of water/bleach solution to heating element area of the Main
Housing and Water Tank.
3. Follow steps 6 and 7 from the scaling section (page 7).
Note: Please be careful of clothing, rugs and other non bleach resistant materials when
disinfecting. Spilling bleach on clothing, rugs and certain surfaces may cause damage.
NOTE: USING MORE THAN 1 TEASPOON OF BLEACH PER GALLON (3.8L) OF WATER WILL
RESULT IN DAMAGE TO YOUR HUMIDIFIER.
Re-Assembling
Step 1
Step 2
1. Push blue Tab to the open position. Place Water Tray and then Mist Chimney back
on the humidifier. Make sure they are sitting securely and blue latch is in the closed
position.
2. Snap Medicine Cup back in place if removed.
3. Put Tank Cap back on Water Tank and place Water Tank back on unit.
End-Of-Season Care And Storage
When the humidifier will not be used for at least one week or more, or at the end of the season,
follow the CLEANING instructions, starting on page 6.
At the end of the season, remove any accessories from the humidifier.
Dry the humidifier completely before storing. DO NOT store with water inside the Main Housing
Water Reservoir or Water Tank.
Pack unit in original carton and store in a cool, dry location.
8
(Continued from page 7)
Step 3
Consumer Relations
Mail questions or comments to:
Call us toll-free at: 1-800-477-0457
E-mail: consumerrelations@kaz.com
Or visit our website at: change to: www.vickshumidifiers.com
TO ORDER REPLACEMENT PARTS CONTACT CONSUMER RELATIONS
Please be sure to specify model number.
Electrical Ratings
The Vicks V750 Series model is rated at 120V, 60 Hz.
NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CONSUMER RELATIONS FIRST
OR SEE YOUR WARRANTY. DO NOT RETURN THE HUMIDIFIER TO THE ORIGINAL PLACE OF
PURCHASE. DO NOT ATTEMPT TO OPEN THE MOTOR HOUSING OR TAMPER WITH INTER-
LOCK SWITCH YOURSELF. DOING SO MAY VOID YOUR WARRANTY AND CAUSE
PERSONAL INJURY OR DAMAGE TO PROPERTY.
Troubleshooting
If your Humidifier is not working properly, refer to the following:
Problem
Possible Cause
• Power Switch is set to
• Unit not plugged in
"On" and Nightlight is off
• No power at outlet
• Little or no mist
• No water in Tank
is produced
• Unit is not level
• Mineral deposits on Heater
Element or Removable Tray
• Water Tank was washed
with detergent
• Reset Light illuminated
• Water Tank is empty
• Unit not reset after refill
• Water overflows from
• Tank may be leaking
Reservoir
• Tank Cap is not tight
• Condensation forms around
• Mist Intensity is set too
humidifier or windows
high for room size or
pre-existing humidity level.
NOTE: Failure to keep this unit clean from mineral deposits normally contained in any water
supply will affect the efficiency of operation of this unit. Customer failure to follow these
instructions may void the warranty.
Solution
• Plug unit in
• Check circuits, fuses, test outlet.
• Fill Water Tank.
• Place on a level surface.
• Follow Cleaning Instructions
on Pages 6-8
• Rinse thoroughly with
clean water.
• Refill Water Tank
• Follow Reset Procedure
• Check the Tank for leaks and
replace if necessary
• Tighten Tank Cap
• Decrease mist output to low
setting or open door to the
room.
9