Controller Instructions
Table of Functions activated by the buttons - Models S, X, Y, C (Table 2)
Button
Pressing the Button Alone
Up
More than 3 sec: toggle ON/
ON/OFF
OFF
Down
More than 3 sec: start/stop
Defrost
defrost
Set Mute
- 1 sec.: display/set the set
point.
- more than 3 secs.: access
parameter setting menu
(enter password )
- mute audible alarm
(buzzer)
Setting the set point (desired temperature)
• Press SET for 1 sec, the set value will start flashing after a few moments.
• Increase or decrease the value using UP or DOWN.
• Press SET to confirm the new value.
Switching the device ON/OFF
Press UP for more than 3 sec. The control and defrost algorithms are now disabled and the Instrument
displays the message "OFF" alternating with the temperature read by the set probe
Manual defrost
Press for DOWN more than 3 sec (the defrost starts only the temperature conditions are valid).
Continuous cycle
Press UP and DOWN together for more than 3 sec.
Access and setting type F (frequent) and type C (configuration) parameters
1. Press SET for 3 sec (the display will show "PS").
2. • To access the type F and C parameter menu, enter the password "22" using UP/DOWN, press SET to
confirm.
• To access the F parameter menu only, press SET (without entering the password).
3. Scroll inside the parameter menu using UP/DOWN.
Normal Operation
Pressed Together
Start/Stop
continuous cycle
-
18
Start Up
-
Pressed
For 1 sec.
together
display
Start parameter
firmware
reset procedure
vers. code
For 1 sec.
RESET cur-
rent EZY set