Cabinet is noisy.
Condensing unit runs for long
periods of time.
Cabinet Temperature Is too warm.
1 YEAR PARTS AND LABOUR / 4 YEARS PARTS ONLY ON COMPRESSOR WARRANTY
Within the warranty period, contact Omcan Inc. at 1-800-465-0234 to schedule an Omcan authorized service
technician to repair the equipment locally.
Unauthorized maintenance will void the warranty. Warranty covers electrical and part failures not improper use.
•
Loose part(s).
•
Tubing vibration.
•
Excessive amount of warm
product Placed in cabinet.
•
Prolonged door opening or
door ajar.
•
Door gasket(s) not sealing
properly.
•
Dirty condenser coil.
•
Evaporator coil iced over.
•
Thermostat set too warm.
•
Blocking air flow.
•
Excessive amount of warm
product Placed in cabinet.
•
Fuse blown or circuit breaker
tripped.
•
Dirty condenser coil.
•
Prolonged door opening or
door ajar.
•
Evaporator coil iced over.
7
Troubleshooting
•
Locate and tighten loose
part(s).
•
Ensure tubing is free from
contact with other tubing or
components.
•
Allow adequate time for
Product to cool down.
•
Ensure doors are closed when
not in use. Avoid opening doors
for long periods of time.
•
Ensure gaskets are snapped
in Completely. Remove gasket
and Wash with soap and water.
Check condition of gasket and
Replace if necessary.
•
Clean the condenser coil.
•
Unplug unit and allow coil to
defrost. Make sure thermostat
is not set too cold. Ensure that
door gasket(s) are sealing
properly.
•
Set thermostat to lower
Temperature.
•
Re-arrange product to allow
for Proper air flow. Make sure
there Is at least four inches of
clearance from evaporator.
•
Allow adequate time for
product to cool down.
•
Replace fuse or reset circuit
breaker.
•
Clean the condenser coil.
•
Ensure doors are closed when
not in use. Avoid opening doors
for long periods of time. (see
above)