The G-BAT automated system for gates with swing leaves is an
operator which transmits movement to the leaf via a worm screw
system.
A handy release system makes it possible to move the gate ma-
nually in the event of a power cut or operator faults.
The G-BAT operator is available in both the 230/115V version and
in the 24V version.
Before you start installing the operator, read this manual to the
letter.
Store the manual for any future references.
Correct operation and the declared technical characteristics
can be obtained only by respecting the indications in this
manual and using GENIUS accessories and safety devi-
ces.
To ensure an adequate degree of safety for the automated
system, the absence of a mechanical clutch device, calls
for the use of a control unit with an adjustable electronic
clutch device.
The G-BAT operator was designed and built to control vehicle
access – AVOID ANY OTHER USES.
Anything not expressly specified in this manual is not permit-
ted.
1. DESCRIPTION
Operator
Transmission pipe
Release key
Rear fastening bracket
Front fastening bracket
Fastening pins
Elastic rings
1.1. TECHNICAL SPECIFICATIONS
Model
Power suply voltage
and frequency
Absorbed power
Absorbed current
Thermal protection
Capacitor
Max.thrust force
Rod stroke
Rod linear speed
Operating ambient temperature
Type and use frequency
Indicative hour cycles at
20°C
Operator weight
Protection class
Maximum leaf length
G-BAT AUTOMATED SYSTEM
Fig. 1
G-BAT Lento
B-BAT
G-BAT
G-BAT
(slow)
115V
24V
115Vac
230Vac 50Hz
24Vdc
60Hz
280 W
350W
70W
1.2 A
3 A
3 A
140 °C
25µF
8µF 400V
250V
350
300
350
300
daN
daN
daN
daN
300 mm / 400 mm
1.6
1.1
1.85
1.6
cm/sec
cm/sec
cm/sec
cm/sec
-20 °C — +55°C
S3 30%
Intensive
≥30
≥20
≥30
≥100
(≥24)
(≥16)
(≥24)
(≥75)
6.5 Kg / 7Kg
IP 54
3 m /4 m
To calculate use frequency, refer to paragraph 1.1.1.
For leaves of over 2.5 m, an electrical lock is necessary to
guarantee leaf blocking
1.1.1. G
RAPH AND USE FREQUENCY
The curve makes it possible to establish maximum work time (T)
according to use frequency
(F).
With reference to standard
IEC 34-1, the G-BAT gearmo-
tor, with service type S3, can
operate at use frequency
of 30%.
To ensure efficient operation,
operate in the work range
under the curve.
The curve is obtai-
ned at a temperature
of 20°C. Exposure to
direct sun rays can
reduce use frequen-
c y d o w n t o 2 0 % .
C
ALCULATION OF USE FREQUENCY
The percentage of effective work time (opening + closing) com-
pared to total time of cycle (opening + closing + pause times).
Calculation fomula:
Ta + Tc
% F = ––––––––––––––––––– X 100
Ta + Tc + Tp + Ti
Where:
Ta =
opening time
Tc =
closing time
Tp =
pause time
Ti =
interval time between one complete cycle and another
1.2. DIMENSIONS
7
Fig. 2