CZAM 670-...
for Siedle Access
Terminal assignment
CZAM 670-...
b1
Supply 12 V AC,
c1
15–32 V DC
D1
Data transmission with
D2
digital call and Vario bus
data transmission
K1
Switching output
("speech" status display)
K2
Switching output
("door opened" status
display)
K3
Switching output
("call" status display)
COM Switching output, collective
contact for K1–3
IN1
Input to external actuation
("door opened" status
display)
L01
RF output
L02
H/L
Impedance high/low
S1
Loudspeaker signal from the
S2
door loudspeaker module
Remarks
• In the Access system, the termi
nals S1 and S2 are only required
if an induction loop system or an
AF amplifier is connected at termi
nals L01, L02.
• To allow the full performance
scope to be used in the Access
system, you must operate the Access
server with the current software
status (from version 1.3.0).
Terminal plans
6 Connection at the Access system
Notes on the wiring diagram
a) The supply limits of the ATLC/
NG 670-... must be observed.
For detailed information, see
Planning and System Manual
Access Professional.
7 In the CZAM 670-..., the status
contacts are connected via a col-
lective contact. The information on
the Vario bus is transmitted via the
RS485 protocol. The contacts are
connected in parallel to the relevant
status LED.
Activating the acoustic feedback
With the CZAM 670-..., activation
of the additional acoustic feedback
for the status messages is carried
out using the Access server admin
istration.
Connection of an external induc-
tion loop system or AF amplifier
Audio OUT: The AF output signal
is applied to terminals L01, L02.
The output impedance is 10 kOhm.
By inserting a bridge from L01 to
H/L, the output impedance is set
from 10 kOhm to 600 Ohm – in
accordance with a 0 dB interface.
8 To output the NF signal on the
CZAM 670-... the audio signal
must be connected to the S1, S2
terminals.
Specifications CZAM 670-...
Output impedance NF signal:
10 kOhm, with bridge 600 Ohm
Operating voltage: 12 V AC,
15–32 V DC
Operating current: 70 mA
Protection system: IP 54
Ambient temperature:
–20 °C to +55 °C
Outputs (K1, K2, K3, COM):
32 V, 1 A
Français
Application
Vers l'affichage optique de l'état
de fonctionnement :
un symbole rétroéclairé par
LED signale les états "Appel",
"Non joignable", "Parler" et
"Porte ouverte".
La signalisation optique peut,
en option, être renforcée par
une confirmation acoustique.
Tension électrique
L'installation, le montage et l'entre
tien d'appareils électriques ne
doivent être réalisés que par un
spécialiste en électricité.
Montage et entretien
Des informations concernant le
montage et le changement de
module figurent dans la notice de
montage de la platine de rue Classic.
1/2 Signalisation optique et
acoustique
1 Appel
2 Non joignable
3 Porte ouverte
4 Parler