Descargar Imprimir esta página

Thermador PH30HS Guía De Planificación página 2

Ventilación
Ocultar thumbs Ver también para PH30HS:

Publicidad

Idiomas disponibles

Idiomas disponibles

Ventilation Planning Guide
It is recommended that a THERMADOR PROFESSIONAL hood is used with a THERMADOR PROFESSIONAL range
or rangetop.
IMPORTANT NOTES:
See related Thermador Manuals for additional information.
Thermador recommends not exceeding 50 equivalent length (ft) (15.24 m) of duct.
Keep duct runs as short and straight as possible. Elbows and transitions fittings reduce air flow efficiency. Back to back
elbows and "S" turns give very poor delivery and are not recommended. A short straight length of duct at the inlet of a remote
blower gives the best delivery.
For Thermador Pro Ranges applications with a non-approved Thermador hood, the hood and/or blower must be rated for 1
CFM for every 100 BTU on the Range/Rangetop. If the range has a Griddle, add an additional 200 CFM to the estimated
blower capacity. If the range has a Grill, add an additional 400 CFM.
For island applications, it is recommended to use a hood width that exceeds the width of the range by 6'' (152 mm),
overlapping the range or rangetop by a minimum of 3'' (76 mm) on each end.
All Blower models referenced may not be compatible with all hoods referenced. Refer to www.thermador.com for a complete
selection of ventilation options, blowers, and accessories.
A 25 foot extension cable (EXTNCB25) is available for purchase to connect the hood to in-line or remote blowers, if required.
The following range and rangetop ventilation combinations are approved installations.
Range or Rangetop
Model
NOTE – All Range/Hood/Blower combinations below must use minimum 6" diameter duct.
30''
PH30HS, HPWB30FS
NOTE – All Range/Hood/Blower combinations below must use minimum 8" diameter duct.
30''
PH30HS, HPCB36NS, HPCN36NS,
HPWB36FS, PH36GS, PH36HS,
VCIB36JP, VCIN36JP,
36'' without Grill or
HPCB36NS, HPCN36NS, HPWB36FS,
Griddle
PH36GS, PH36HS, VCIB36JP,
36'' with Griddle
VCIN36JP, PH42GS, HPCB48NS,
HPCN48NS, HPWB48FS, PH48GS,
PH48HS, VCIB48JP, VCIN48JP
48'' with Griddle only
HPCB48NS, HPCN48NS, HPWB48FS,
PH48GS, PH48HS, VCIB48JP,
VCIN48JP, PH54GS, VCIB54JP,
VCIN54JP
NOTE – All Range/Hood/Blower Combinations below must use minimum 10" diameter duct.
36'' With Grill
HPCB36NS, HPCN36NS, HPWB36FS,
PH36GS, PH36HS, VCIB36JP,
VCIN36JP, PH42GS, HPCB48NS,
HPCN48NS, HPWB48FS, PH48GS,
PH48HS, VCIB48JP, VCIN48JP
48'' with Grill
HPCB48NS, HPCN48NS, HPWB48FS,
48" with Grill and
PH48GS, PH48HS, VCIB48JP,
Griddle
VCIN48JP, PH54GS, VCIB54JP,
VCIN54JP
* Indicates a letter designating the release year.
Recommended
Hood Models
9001007032 • Rev. A • 5U063E • © BSH Home Appliances Corporation, 08/14
Min. Integral
Min. In-Line or
Blower
Remote Blower
VTN630*,
VTI610*,
VTN600*
VTR630*
VTN1000*
VTI1010*,
VTR1030*
VTN1030*,
VTI1010*,
VTN1080*,
VTR1030*
VTN1000*
VTN1030*,
VTI1010*,
VTN1080*,
VTR1030*
VTN1000*
VTN1030*,
VTI1010*,
VTN1080*
VTR1030*
VTN1030*,
VTI1010*,
VTN1080*
VTR1030*
Other Available
Blowers
N/A
VTN1030*, VTN1080*,
VTI1010*, VTR1030*,
VTR1330*
VTR1330*
VTR1330*
VTR1330*
VTR1330*

Publicidad

loading