Delivery Scope - Brita PURITY 450 Steam Manual

Ocultar thumbs Ver también para PURITY 450 Steam:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 90
The pressure vessel and the pressure vessel lid of the filter systems have a service life of up
to ten years (from the date of installation), provided that they are installed and used correctly
and the operating conditions outlined in the Technical Data chapter are adhered to. They must
always be replaced after a maximum of ten years. The hoses must be replaced in rotation after
a maximum of five years.
Production date:
Production code sticker filter cartridge and box, example: B612002010
6
Production year, here: 2016
12
Production week, here: calendar week 12
002
Batch No. of filter medium, here the second batch filled in terms of quantity
010
Serial number of the filter cartridge, here the tenth cartridge from the second batch
Production code sticker connector head - Example: 1001801 E 619316008764
1001801 BRITA identification number
E
Supplier ID
6
Production year, here: 2016
19
Production week, here: calendar week 19
3
Production day from Monday (1) to Friday (5), here: Wednesday
16
Production year, here: 2016
008764
Serial identification number
Production date of pressure vessel and pressure vessel lid, example: 0315
03
Production month, here: March
15
Production year, here: 2015
3.5 Safety Assembly Instructions
The terminal device operated with the filter must be free of limescale prior to installation.
Protect the filter system from sunlight and mechanical damage. Do not assemble near sources
of heat and open flames.
A stop valve must be installed before the filter system intake hose.
If the water pressure is higher than 6.9 bar or if there are statutory requirements, a pressure
reducer must be installed before the filter system.
EN
A non-return valve tested by the DVGW has been factory-installed at the water intake of the
filter head.
No copper pipes and no galvanised or nickel-plated pipes/connectors may be installed between
the water filter and the consumer. The use of BRITA hose sets is recommended here. When
choosing the material for parts that come into contact with water after the BRITA filter system
it must be remembered that, due to the process, decarbonised water contains free carbon
dioxide.
All parts must be installed in accordance with the country-specific guidelines on the installation
of drinking water facilities.
For erection and operation of the filter system, the BG rules "Working in Kitchens" of the Spe-
cialist Committee "Foods" of the BGZ (BGR111) must be observed.
4 Installation
Caution: Prior to installation, read the Technical Data (Chapter 12) and the Operating and Safety
!
Information (Chapter 3). After the product has been stored and transported at temperatures below
0°C, it must be stored with the original packaging open for at least 24 hours at ambient temperature
(Chapter 12) before commissioning.

4.1 Delivery Scope

Prior to installation, remove the entire delivery scope from the packaging and check that everything
is present:
1 x Pressure Vessel
1 x Pressure Vessel Lid
22
1
3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Purity 600 steamPurity 1200 steam

Tabla de contenido