5. Electrical work
Manual vane angle
Main
Main menu
Maintenance
Initial setting
Service
Main display:
Cursor
Page
F1
F2
F3
F4
Maintenance menu
Auto descending panel
Manual vane angle
3D i-See sensor
Main menu:
Cursor
F1
F2
F3
F4
Manual vane angle
M-NET address
Identify unit Check button
Input display:
Address
Check
F1
F2
F3
F4
Manual vane angle
Select:
Outlet
Angle
F1
F2
F3
F4
Manual vane angle
Setting
1 Select "Maintenance" from the Main
menu, and press the [SELECT]
button.
2 Select "Manual vane angle" with the
[F1] or [F2] button, and press the
[SELECT] button.
3 Select the "M-NET address" for the
with the [F2] or [F3] button, and press
the [SELECT] button.
unit.
The vane of only the target indoor
unit is pointing downward.
4 The current vane setting will appear.
Select the desired outlets from 1
through 4 with the [F1] or [F2] button.
4, (all outlets)"
Press the [F3] or [F4] button to go
through the option in the order of
"No setting (reset)," "Step 1", "Step
2", "Step 3", "Step 4", "Step 5" and
"Draft reduction*".
Select the desired setting.
* Draft reduction
T h e a i r f l o w d i r e c t i o n f o r t h i s
setting is more horizontal than the
airflow direction for the "Step 1"
setting in order to reduce a drafty
feeling. The draft reduction can be
set for only 1 vane.
Vane setting
No setting
Step 1
Step 3
Step 4
Draft
All
reduction*
outlets
Press the [SELECT] button to save the settings.
A screen will appear that indicates the setting information is being
transmitted.
The setting changes will be made to the selected outlet.
The screen will automatically return to the one shown above (step 5)
when the transmission is completed.
Make the settings for other outlets, following the same procedures.
If all outlets are selected,
goes into operation.
Navigating through the screens
.........................[MENU] button
....................[RETURN] button
Manual vane angle
M-NET address
Identify unit Check button
Input display:
Address
Check
F1
F2
F3
F4
Manual vane angle
M-NET address
Function setting for unit
with vane fully open.
Return:
F1
F2
F3
F4
Manual vane angle
No communication
Check Unit state.
Return:
F1
F2
F3
F4
Step 2
Step 5
1 Select the "M-NET address" for the
with the [F2] or [F3] button.
Press the [F4] button to confirm
the unit.
2 After pressing the [F4] button, wait
approximately 15 seconds, and
then check the current state of the
air conditioner.
on the remote controller.
the [RETURN] button and contin-
ue the operation from the begin-
ning.
device does not exist at this refrig-
erant address.
turn to the initial screen.
3 Change the "M-NET address" to
the next number.
1 to change the
"M-NET address" and continue
-