Before starting the process of install the pump it is a must to read this manual of oper-
ations carefully. The installation must be according with the local standard.
Applications
1
The pump for swimming pool CLEO.2 are a centrifugal type and with horizontal construction.
Its main function is to make circulate the water, normally settle in Spas. The pump can also
be installed for its use in swimming pools connected to a prefilter. The pump is designed to
remove clean waters coming from one SPA or a swimming pool disinfected by chlorination.
Technical Data
2
2.1 Environmental temperature
Maximun + 50ºC.
2.2 Temperature of the water
From 0ºC to + 50ºC.
2.3 Principle allowed pressure of work
2 bar (that possible water hammers do not exceed 3 kgs).
2.4 Principle inlet pressure
When the water pump works against a closed valve the presure must be always lower that
the maximun allowed pressure of work.
2.5 Electrical Data
Voltage: 1x220/230V 50Hz
See also identification plate.
Type of protection: IP 55.
Class of isolation: Class F.
2.6 Dimensions
Please see the figure at the end of these instructions.