Descargar Imprimir esta página

Personal Safety; Device Description - STAMOS S-LS-46 Manual De Instrucciones

Publicidad

d)
If there are any doubts as to the correct operation
of the device, contact the manufacturer's support
service.
e)
Only the manufacturer's service point may repair the
device. Do not attempt any repairs independently!
f)
In case of fire, use a powder or carbon dioxide
(CO
) fire extinguisher (one intended for use on live
2
electrical devices) to put it out.
g)
Children or unauthorised persons are forbidden to
enter a work station. (A distraction may result in loss
of control over the device).
h)
Use the device in a well-ventilated space.
i)
Regularly inspect the condition of the safety labels. If
the labels are illegible, they must be replaced.
j)
Please keep this manual available for future
reference. If this device is passed on to a third party,
the manual must be passed on with it.
k)
Keep packaging elements and small assembly parts
in a place not available to children.
l)
Keep the device away from children and animals.
m)
When working with the device, harmful fumes are
generated. The workplace must be well ventilated
to protect unauthorized persons from the harmful
effects of fumes
REMEMBER! When using the device, protect
children and other bystanders.

2.3. PERSONAL SAFETY

a)
Do not use the device when tired, ill or under the
influence of alcohol, narcotics or medication which
can significantly impair the ability to operate the
device.
b)
The device is not designed to be handled by persons
(including children) with limited mental and sensory
functions or persons lacking relevant experience
and/or knowledge unless they are supervised by
a person responsible for their safety or they have
received instruction on how to operate the device.
c)
The device can be handled only by physically fit
persons who are capable of handling it, properly
trained, familiar with this manual and trained within
the scope of occupational health and safety
d)
When working with the device, use common sense
and stay alert. Temporary loss of concentration while
using the device may lead to serious injuries.
e)
Use personal protective equipment as required
for working with the device, specified in section 1
(Legend). The use of correct and approved personal
protective equipment reduces the risk of injury.
f)
To prevent the device from accidentally switching on,
make sure the switch is on the OFF position before
connecting to a power source.
g)
Do not overestimate your abilities. When using the
device, keep your balance and remain stable at all
times. This will ensure better control over the device
in unexpected situations.
h)
The device is not a toy. Children must be supervised
to ensure that they do not play with the device.
2.4. SAFE DEVICE USE
a)
Do not overload the device. Use the appropriate
tools for the given task. A correctly-selected device
will perform the task for which it was designed better
and in a safer manner.
EN
b)
Do not use the device if the ON/OFF switch does not
function properly (does not switch the device on and
off). Devices which cannot be switched on and off
using the ON/OFF switch are hazardous, should not
be operated and must be repaired.
c)
Disconnect the device from the power supply
before commencement of adjustment, cleaning and
maintenance. Such a preventive measure reduces
the risk of accidental activation.
d)
When not in use, store in a safe place, away from
children and people not familiar with the device who
have not read the user manual. The device may pose
a hazard in the hands of inexperienced users.
e)
Keep the device in perfect technical condition.
Before each use check for general damage and
especially check for cracked parts or elements and
for any other conditions which may impact the safe
operation of the device. If damage is discovered,
hand over the device for repair before use.
f)
Keep the device out of the reach of children.
g)
Device repair or maintenance should be carried out
by qualified persons, only using original spare parts.
This will ensure safe use.
h)
To ensure the operational integrity of the device, do
not remove factory-fitted guards and do not loosen
any screws.
i)
Do not touch articulated parts or accessories unless
the device has been disconnected from the power
source.
j)
Do not leave this appliance unattended while it is in
use.
k)
Clean the device regularly to prevent stubborn grime
from accumulating.
l)
The device is not a toy. Cleaning and maintenance
may not be carried out by children without
supervision by an adult person.
m)
It is forbidden to interfere with the structure of
the device in order to change its parameters or
construction.
n)
Keep the device away from sources of fire and heat.
o)
Only use rosin flux for soldering..
p)
n) Always place the soldering iron on the holder if it
is not in use.
q)
Keep the soldering tip and parts that can get hot
away from your body, clothing and flammable
objects / substances.
r)
The soldering tip remains hot even after the power
is turned off. Before cleaning or replacing parts, wait
until the device has cooled down completely..
s)
Do not leave the soldering station set at the highest
temperature for a long time.
ATTENTION! Despite the safe design of the device
and its protective features, and despite the use of
additional elements protecting the operator, there
is still a slight risk of accident or injury when using
the device. Stay alert and use common sense when
using the device.
3. USE GUIDELINES
The soldering station with the fume extractor is used to
permanently join metal pieces together by means of solder
and to extract fumes generated during the soldering
process.
The user is liable for any damage resulting from
unintended use of the device.
25.03.2019
8

3.1. DEVICE DESCRIPTION

3
4
2
5
7
1
6
10
9
8
12
11
17
16
15
14
13
20
19
18
1.
Control panel
2.
Exhaust fan
3.
Fan cover
4.
Filter
5.
Filter stabilizer
6.
Cleaning wire
7.
Soldering iron rack
8.
ON / OFF switch
9.
Temperature control dial
10.
Fan LED
11.
Power cord socket
12.
Grounding socket
13.
Soldering tip fastening nut
14.
Soldering tip housing
15.
Soldering tip
25.03.2019
EN
16.
Nut joining the heater and plate to wires
17.
Spring
18.
Heater
19.
Plate with wires
20.
Handle
3.2. PREPARING FOR USE
APPLIANCE LOCATION
The temperature of environment must not be higher than
40°C and the relative humidity should be less than 85%.
Ensure good ventilation in the room in which the device
is being used. There should be at least 10 cm distance
between each side of the device and the wall or other
objects. The device should always be used when positioned
on an even, stable, clean, fireproof and dry surface, and
be out of the reach of children and persons with limited
mental and sensory functions. Position the device such that
you always have access to the power plug. The power cord
connected to the appliance must be properly grounded
and correspond to the technical details on the product
label.
Disassemble the device and all its components and clean
them before the first use.
ASSEMBLING THE APPLIANCE
1.
Unpack the soldering station with the exhaust fan.
2.
Carefully unpack the soldering station components.
3.
Check
that
the
unwrapped
components
undamaged. If any damage is visible, contact the
manufacturer immediately.
4.
Place the cleaning wire in the soldering iron holder.
5.
Open the fan cover.
6.
Place the filter on the filter stabilizer and install both
inside the fan.
7.
Connect the soldering iron cable to the soldering
station.
8.
Put the soldering iron on the rack.
3.2. DEVICE USE
1.
Position the exhaust fan so that the fumes generated
during soldering are sucked away.
2.
Place the rack with the soldering iron in a comfortable
position.
3.
Connect the soldering station to the power source.
4.
Set the temperature to 250°C by turning the
temperature dial.
5.
Press the ON / OFF switch. The sound of the fan and
the glowing LED indicate that the soldering station is
on.
6.
Set the desired temperature 3 minutes after
switching the device on.
7.
After finishing work, set the temperature to 250°C
and turn the device off using the ON / OFF key.
8.
The fan LED will go out.
NOTE: Over the long-term operation of the soldering
station, the filter in the air extraction system will gradually
become contaminated and stop absorbing the toxic fumes
generated during soldering.
9
are

Publicidad