Temperature Alarm Function Selection Parameter
MODBUS ADRES:40026
Temperature alarm function is inactive.
Absolute alarm is selected. If temperature lower than
, then alarm is on.
Relative alarm is selected. Alarm operates according to the set value. If cabinet
temperature value is below ( Set -
Temperature Alarm Minimum Parameter
(Default = Minimum Value of Device Scale) MODBUS ADRES:40027
For
= 1, this parameter value can be adjusted from minimum value of device
scale to temperature alarm maximum parameter
parameter value can be adjusted 0 to %50 of the device scale.
Temperature Alarm Maximum Parameter
(Default =Maximum Value of Device Scale ) MODBUS ADRES:40028
For
= 1, this parameter value can be adjusted from temperature alarm minimum
parameter
value to maximum value of device scale.For
value is can be adjusted 0 to %50 of the device scale.
Temperature Alarm On Delay Time Parameter
MODBUS ADDRESS:40029
Temperature Alarm On Delay Time can be defined with this parameter. It can be
adjusted from 0 to 99 minutes.
Temperature Alarm Delay After Power On Parameter
MODBUS ADDRESS:40030
When power is first applied to the device, this time delay must be expired for activation of
temperature alarm.
It can be adjusted from 0 to 99 minutes.
Fan Operation Selection Parameter (Default = 1) MODBUS ADDRESS:40031
Fan is OFF.
Fan is ON.
Fan operates according to the evaporator sensor temperature value.
Fan operates according to the ( cabinet - evaporator ) temperature value.
Fan Stopping Temperature Parameter
Fan stopping temperature can be defined with this parameter.
minimum value to maximum value of device scale.
Hsyteresis Parameter for Fan Output (Default = 1 ) MODBUS ADDRESS:40033
From 1 to 20°C for NTC (-50°C, 100°C) , from 1 to 36°F for NTC (-58°F, 212°F), from
0.1 to 10.0°C for NTC (-50.0°C,100.0°C), from 0.1 to 18.0°F for NTC (-58.0°F,212.0°F)
Fan Activity Selection According to the Compressor and Defrost
(Default = 0) MODBUS ADDRESS:40034
Fan operates according to the
Fan operates according to the
commpressor is stops.
Fan operates according to the
defrost and dripping time.
Fan operates according to the
defrost and dripping operations fan stops.
Fan Delay Time After Completion of Dripping Time Parameter (Default = 2)
MODBUS ADDRESS:40035
Fan Delay Time After Completion of Dripping Time is defined with this parameter.
It can be adjusted from 0 to 15 minutes.
( Default = 0 )
) or above ( Set +
value. For
(Default = 0)
(Default = 0)
(Default = 2°C) MODBUS ADDRESS:40032
It can be adjusted from
parameter.
parameter, but fan is stopped if
parameter, but fan is stopped during
parameter.If compressor stops, during
and higher than
), alarm ocurs.
= 2, this
= 2, this parameter
11