WATER CONNECTIONS

Carefully comply with any national or
regional regulations in force.
Water installation must have the following
characteristics:
Temperature: 55°C
Dynamic Pressure :
2 ÷ 4 bar (200÷400 kPa);
-
-for machines with incorporated Water-
softener :
Temperature: 10÷12°C
Dynamic Pressure : 3 ÷ 4 bar
400 kPa).
WARNING!
If the water pressure is higher than 3 bar, fit
the pressure reducer "A" supplied into the
solenoid valve as shown in the drawing.
If the dynamic pressure is lower than
specified on the data plate of the machine,
it is advisable to install a Booster Pump.
Hardness: between 7,2 and 12,5 °French.
If the hardness values are higher than
those mentioned above, it is advisable to
install a water-softener.
WORKS TEMPERATURES
Water temperature 55°÷60°C
Rinse temperature 80°÷85°C
DO
THERMOSTAT CALIBRATION

WATER DRAIN

According
drawing; water drain and feeding pipe
should have the same diameter as the
water inlet of the machine.
(300 ÷
It must be furnished with a siphon and have
a right slope.
The machine is provided with a flexible pipe
for the connection with the water-work.
Make sure there are no throttlings along the
pipe.
Carefully comply with any national or
regional regulations in force.
39
NOT
TAMPER
to
the
dimensions
WITH
THE
of
the