Réf. : 134 08 02
Figure 2 - Smoke exit from top
1 - Flue collar
2 - Ceramic rope
3 - Blanking plate
2.4. Assembly of flue spigot and blanking
plates
The stove is supplied with a connection flue spigot with
an inner diameter of 125 mm and an outer diameter of
139 mm.
2.4.1. Smoke exit on the top
Figure 2
• Remove the top plate.
• Fit the sealing rope 2 in the groove on the top and fix
the flue collar 1 with 3 bolts and washers supplied.
• Replace the top plate.
2.4.2. Smoke exit at rear
Figure 4
• Remove the top plate.
• Remove the rear heat shield and remove the cut-out
on it (fig. 3).
• Remove the retainer fuel (fig. 7, p. 18), the two side
bricks # 23 and 24 p. 22) and the flue baffle (fig. 8,
p. 18).
• Remove the blanking plate 3 and the clamp 4 and
assembly in the top, ensuring there is a good seal.
• Fix the flue collar 1 at rear with 3 bolts and washers
supplied, ensuring there is a good seal.
• Remove the cut-out in the rear heat shield and re-fit.
• Replace top plate.
Notice de référence
"SAVOY"
4 - Clamp
5 - Top plate
Document n° 955-1EN ~ 25/11/1998
Figure 3 - Rear heat shield
Figure 4 - Rear flue outlet
1 - Flue collar
2 - Ceramic rope
3 - Blanking plate
Poêle à bois
4 - Clamp
5 - Top plate
17