1 - Keep pressing MENU (left key) and
rature setting) simultaneously for 3 seconds to
FR
access installer mode.
2 - Choose parameter to change using
keys
ES
3 - Press
4 - Set the parameter using
PT
5 - Press
6 - Press
IT
Param.
1LA
EL
2CR
3OT
4LL
PL
5UL
6SO
9LC
UA
10BL
11CL
12DS
RO
13TO
15SD
16FS
EN
17OP
19LK
Type of Control
Electrical protection
Type of Batteries
Temperature range
Action
Rated current
Environment
Regulation class
(according 811/2013)
Energy effi ciency gain (contribution to seasonal space heating energy effi ciency)
Class of Software
Radio frequency
Maximum power of radio emission
Supplier
Hereby, Adeo Services, declares that the radio equipment 82823694 / TH50DP6RF is in compliance
with Directive 2014/53/UE. The full text of the EU declaration of conformity is available at the following
internet address : http://www.erp-equation.com/Regulation/
84
to change a parameter,
and
to validate
to exit installer mode
Description
Display language
Cycle Rate
Minimum boiler ON time
Lower temperature limit
Upper temperature limit
Type of programmation
Fail Safe
Backlight
Clock format
Daylight saving
Temperature off set
Reset schedule
Factory reset
Optimum start
Lock options
Independently mounted battery powered digital room thermostat for surface
mounting
IP30
CLASS II
2 batteries AA (LR06 ) 1,5 V (not supplied)
5-35°C
Micro-interrupt, Type 1 .C
Rated voltage : 24-230V~, 50-60Hz - Max rated current for Resistive load : 5A
Max rated current for Inductive load : 3A
Pollution degree = 2 (standard household conditions without conductive dust)
Class IV
Class A
868.0-868.6 MHz, 1% Duty Cycle
ADEO Services - 135 Rue Sadi Carnot, CS 00001, 59790 - RONCHIN - FRANCE
(tempe-
and
1
keys
Values range
1=EN, 2=NL, 3=FR, 4=DE, 5=IT, 6=ES,
7=PT,8=CZ, 9=HU, 10=PL, 11=RO, 12=SK, 13=HR
1=7 days, 2=5+2 days
0=Disabled, 1= Enabled
0=Disabled, 1= Enabled
0=24h, 1=12h
0=Disabled, 1= Enabled
0=Disabled, 1= Enabled
1=Partial, 2=Total
Technical data
No protection against water ingress
Product that does not incorporate protective earthing provision,
but a double insulation as provision against electric shock
Rated impulse voltage
Overvoltage Category according IEC/EN 60730-1
25mW
3s
3, 6, 9, 12
1.....5 min
5....21°C
21....35°C
-3.......+3°C
0, 1 (Reset)
0, 1 (Reset)
1
Default value
1=EN
6
1 min
5°C
35°C
1=7 days
0=Disabled
1= Enabled
0=24h
1= Enabled
0
0
0
0=Disabled
1=Partial
2500 V
2%
II