3. Specifications
Model
Noise level (50/60 Hz)
External static pressure
Indoor units
Total capacity
Model
Quantity
Operation
Standard type
temperature
Fresh air intake
type
4. Confirmation of parts attached
1 Wire clamping plate
Model
P700 ~ P800
5 Connecting pipe for indoor unit
(gas side ø34.93)
Model
P700 ~ P800
9 Connecting pipe for indoor unit
(liquid side) <bottom piping>
Model
P700 ~ P800
Note:
The crossover connecting pipes 0 0 0 0 0 and A A A A A can be used for the standard installation
(installing the compressor unit (Right side) and heat exchanger unit (Left side) with a gap of 10 mm in between).
5. Space required around unit
[Fig. 5.0.1] (P.2)
<A> Top view
<C> When there is little space up to an obstruction
A Front
B No restrictions on wall height (left and right)
C Air outlet guide (Procured at the site)
E Heat exchanger unit
G Wall height (H)
(mm)
L
L
L
1
2
3
450
100
250
(1) Basic space required
(2) When there is an obstruction above the unit
(3) When inlet air enters from right and left sides of unit
•
Wall heights "H" of the front and the back sides shall be within total height of
unit.
•
When wall height "H" exceeds total height of unit, add "h" dimension to L
L
of the Fig. 5.0.1.
2
"h" = wall height "H'" – total height of unit
6. Lifting method
[Fig. 6.0.1] (P.2)
Caution:
Be very careful to carry product.
- Do not have only one person to carry product if it weighs more than 20 kg.
- PP bands are used to pack some products. Do not use them as a mean for transportation because they are dangerous.
- Do not touch heat exchanger fins with your bare hands. Otherwise you may cut your hands.
- Tear plastic packaging bag and scrap it so that children cannot play with it. Otherwise plastic packaging bag may suffocate children to death.
- When carrying outdoor unit, be sure to support it at four points. Carrying with 3-point support may make outdoor unit unstable, resulting in it falling.
8
PUHY-P700
62 dB<A>
Cooling mode: – 5 °CDB ~ 43 °CDB (0 °CDB ~ 43 °CDB with outdoor unit at lower position)
Heating mode: – 20 °CWB ~ 15.5 °CWB
Cooling mode: 21 °CDB ~ 43 °CDB
Heating mode: – 12.5 °CWB ~ 20 °CWB
2 Conduit mounting plate (ø53)
1 pc.
1 pc.
6 Packing (inside ø23, outside ø35)
1 pc.
1 pc.
0 Crossover connecting pipe be-
tween the compressor unit and
heat exchanger unit (gas side)
1 pc.
1 pc.
<B> Side view
D Compressor unit
F Must be open
H No restrictions on wall height
1
PUHY-P750
63 dB<A>
0 Pa
50 ~130 %
20 ~ 250
1 ~ 34
3 Tappinng screw M4
4 pcs.
7 Packing (inside ø29, outside ø39)
1 pc.
A Crossover connecting pipe be-
tween the compressor unit and
heat exchanger unit (liquid side)
1 pc.
(4) When unit is surrounded by walls
Note:
•
Wall heights "H" of the front and the back sides shall be lower than either
the front or the back panel.
•
If the panel height is exceeded, add the "h" dimension of the Fig. 5.0.1 to
L
and L
.
1
2
(mm)
L
L
1
2
450
450
Example: When the "h" dimension is 100 mm,
the L
dimension becomes 450 + 100 = 550 mm.
1
the L
dimension becomes 100 + 100 = 200 mm.
2
(5) Collective installation and continuous installation
•
Space required for collective installation and continuous installation:
When installing several units, provide the space between each block consider-
ing passage for air and people.
and
•
Open in two directions.
•
In case of wall height "H" exceeds total height of unit, add "h" dimension (h =
wall height "H'" – total height of unit) to * marked dimension.
•
If there is a wall at both of the front and the rear of the unit, install up to two sets
(heat exchanger unit and compressor unit: two units each) consecutively in
the side direction and provide a space of 1,000 mm or more for air inlet space/
passage space for each two sets.
PUHY-P800
64 dB<A>
4 Connecting pipe for heat ex-
changer unit (gas side ø28.58)
1 pc.
8 Connecting pipe for indoor unit
(liquid side) <front piping>
1 pc.