Logic
Definition
Fixed code
FIXED CODE
Transmitter pro-
RADIO PROG
gramming
Serial mode
(Identifies how board
SERIAL MODE
is configured in a BFT
network connection).
Address
ADDRESS
Configuration of
EXPI1 input on
input-output expan-
EXPI1
sion board.
1-2
INSTALLATION MANUAL
Cross out
Default
setting
used
Receiver is configured for operation in rolling-code mode.
0
Fixed-Code Clones are not accepted.
0
Receiver is configured for operation in fixed-code mode.
1
Fixed-Code Clones are accepted.
Disables wireless memorizing of transmitters.
Transmitters are memorized only using the relevant Radio menu.
0
IMPORTANT: This high level of security stops unwanted clones from gaining access and also
stops radio interference, if any
Operations in this mode are carried out near the control panel and do not require access:
A - Enables wireless memorizing of transmitters:
- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already
been memorized in standard mode via the radio menu.
1
- Press within 10s the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other new transmit-
1
ters by repeating the previous step.
B-Enables wireless automatic addition of clones and replays.
Enables clones generated with the universal programmer and programmed replays to be added to
the receiver's memory.
0
Standard SLAVE: board receives and communicates commands/diagnostics/etc.
Standard MASTER: board sends activation commands (START, OPEN, CLOSE, PED, STOP) to other
1
boards.
0
SLAVE opposite leaves in local network : the control unit is the slave in an opposite leaves network
2
with no smart module (fig.F)
MASTER opposite leaves in local network: the control unit is the master in an opposite leaves net-
3
work with no smart module (fig.F)
Identifies board address from 0 to 119 in a local BFT network connection.
[ ___ ]
0
(see U-LINK OPTIONAL MODULES section)
0
Input configured as Start E command.
1
Input configured as Start I command.
2
Input configured as Open command.
3
Input configured as Close command.
4
Input configured as Ped command.
5
Input configured as Timer command.
6
Input configured as Timer Pedestrian command.
7
Input configured as Phot (photocell) safety.
1
8
Input configured as Phot op safety (photocell active during opening only).
9
Input configured as Phot cl safety (photocell active during closing only).
10
Input configured as Bar safety (safety edge).
Input configured as Phot test safety (tested photocell).
11
Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device test
input, EXPFAULT1.
Input configured as Phot op test safety (tested photocell active during opening only).
12
Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device test
input, EXPFAULT1.
Input configured as Phot cl test safety (tested photocell active during closing only).
13
Input 3 (EXPI2) on input/output expansion board is switched automatically to
safety device test input, EXPFAULT1.
Input configured as Bar safety (tested safety edge).
14
Input 3 (EXPI2) on input/output expansion board is switched automatically to
safety device test input, EXPFAULT1.
Optional extras
SIRIO CBA 230 INV
23
-