The chimney should be one metre higher than
the highest part of the house. If you need to increase
the draw, extend the length of the chimney.
Minimum 1m
higher
Incorrect
The covers must not affect the draw
Que los sombreretes no dificulten el tiro.
INCORRECTO
Incorrect
• It is advisable to clean the chimney at least once a
year.
In order to access the chimney for cleaning purposes,
observe the following instructions:
a)
Remove the deflection plate (follow the
instructions described in chapter 6 "cleaning".
b)
Once the deflection plate has been removed,
you will be able to access the chimney. Clean the
conduit using a special chimney brush with a weight
as described in fig. 1.
These steps must be performed whenever the device
has been unused for a long period of time to ensure
no blockage exists before lighting it.
Fig.1
Mínimo 1 m.
por encima
Correct
(Ø)
CORRECTO
Correct
• The joints of the pipes that form the chimney, in
the case of metal pipes, must be sealed with refractory
putty.
The female coupling of the pipes must face
upwards to avoid any possible creosote from leaking out.
External metal chimneys must be built with
special double insulated pipes for solid fuels.
1.2.5 Installation using existing chimneys.
When using existing chimneys, it is advisable to
place one or two metres of metal pipe inside the existing
chimney and ensure that the gap between the brickwork
chimney and the pipes has been sealed (see figure).
The inside section of the chimney must be perfectly
insulated so that it is capable of resisting the high
temperatures reached by the insert fireplace.
Insulation should be placed on the internal walls,
allowing air to flow around the insert fireplace. Never
place insulation around the insert fireplace; this may
damage the unit if heat is unable to dissipate. The metal
chimney should not be wrapped with insulating fibre.
Mínimo
Minimum
igual al Ø
Equal to Ø
Internal insulation must not prevent the passage
of air through the hood ventilation grilles.
Insulating fibre used inside must resist high
temperatures and must not produce any odour when
heated.
If the chimney should catch fire (an excessive
accumulation of creosote may ignite), close all air input to
the device (primary and secondary) and even close air
input to the room where the device has been installed.
This will cause the flame to go out by themselves.
IMPORTANT
Never let the full weight of the chimney lie on the
6
Insert Fireplace. This could damage it.