Descargar Imprimir esta página

Bticino 322031 Manual De Usario página 3

Publicidad

Idiomas disponibles

Idiomas disponibles

• Function setting
1. Reset to Default configuration.
The original room number for all keys as below:
503
501
403
401
303
301
203
201
103
101
EP(322031 20pbs)
When the device is in standby status, press the reset key at the back of the device about 6 seconds,when we hear one long "di", which indicates the reset is successful.
2. EP 's address and keys can be loaded by SF2
Detail information about the operation can be according to the SF2 manual.
3. Room mode setting.
Put jumper on "RM"
position at the back of the device, then set the #F#F (floor), #I#I(room),and pressing the key we needed on the front of the panel, we will hear one
long "di" ,which indicates configuration is successful.
For example: if we want to configure the first key left at the front of the panel as 203. Steps as below:
c) Put the jumper on "CF"
d) Insert the configuration resistors "0" and "2" into "#F#F", "0"and"3"into "#I#I".
e) Press the first key left at the front of the panel, if we hear a long "di" sound and indicate success. If you hear three short "di", indicate wrong configuration.
attention that we can not configure #F#F and #I#I as 00.
f ) Other keys configuration as the steps as c, d, e. if we finished all of the
Pay configuration of keys , and then insert jumper into "NA"
The configuration is finished.
4. SCS address setting mode.
Put jumper on "CF"
at the back of the device. Insert different configuration resistors into the #F#F(floor), #I#I(room),and then press the related key, if we hear a long
"di" sound and which indicates configuration is successful.
For example: if we want to configure the first key left at the front of the panel as 0123. Steps as below:
g) Put the jumper on "CF"
h) Configure #F#F#I#I as 0 1 2 3;
i) Press the first key left at the front of the panel, If we will hear one long "di",indicate success, if you hear three short "di", indicate failure.
The maximum of the SCS configuration address can't be over 4000.
j) The other keys configuration of steps like as g, h ,i. if we finished all of the configuration of keys , and then insert jumper into "NA"
The configuration is finished.
5. " Management center calling" configuration.
The configuration of management center is the same as SCS address setting mode. But the management center address was defined. Means "#F#F #I#I" must be inserted into
"40 00" .
6. Set the number of apartment per floor
When put jumper on "CF"
per floor is 4.
7. Lock status setting.
Press the reset key
at the back of the device for 3s when the device is in standby status, If we hear a long "di" sound, indicates the device read the lock status already.(always
on or off ),but when we set up the lock status we must close the gate, doing this way, we can know the status of lock if it is close or not. And the device will pass this message to
management center. And guard will know the door is not close well. but we need to care the time, if continue to press the reset key for another 3s , the device will reset the
default when we hear another long "di" sound.
8. Setting anti-thief.
This function just prevent the device to be moved. Then device will send message to management center to alarm if device is moved by someone.
There are two switches at the back of the device, one is the enable switch of anti-thief, the other is an anti-thief switch. the anti-thief switch will be available when you push the
enable switch to "ON" position
504
502
404
402
304
302
204
202
104
102
EP (322030 10 pbs)
, then Put jumper on "RM"
at the back of the device.
, then Put jumper on "SCS"
, " NN"indicates the number of apartment per floor,for example "02" indicates 2 apartment per floor, and the default number of apartment
.
302
301
204
203
202
201
104
103
102
101
at the back of the device.
at the back of the device
3
at the back of the device.

Publicidad

loading

Este manual también es adecuado para:

322030