8
1
12
9
13
2
10
3
11
14A
15A
14
15
16
17
18
19
1
Welding current, [A]
2
Wire feed speed, [m/min.]
3
Thickness of material, [mm]
4
Welding voltage, [V]
5
Trim voltage, [V]
6
Arc adjust
7
Seam average log –
current/voltage
8
Lock symbol
Lock: Insert the SD lock card and choose
"1", "2" or "All" using (15).
Unlock: Reinsert the SD lock card to unlock
the control panel. For detail information,
see instruction manual.
9
Warning – overheating
4
10
Info – globular transfer
5
Risk of weld spatter.
6
7
11
Fault indicator –
see instruction manual
12
Display of welding current, wire
feed speed or thickness of material
13
Display of trim voltage,
welding voltage or Arc adjust
20
14
Setting welding current/
Selecting welding program
Turn the control knob to set the desired
welding current.
Short press (14A): Change between display
of welding current, wire feed speed or
thickness of material.
Long press (14A): Select welding program.
15
Setting welding voltage,
Arc adjust and welding process
Turn the control knob to set the desired
welding voltage or Arc adjust.
Short press (15A): Change between display
of trim voltage, welding voltage, Arc adjust
or seam average (welding current/voltage).
Long press (15A): Opens for setting the
welding process (figure 1).
QUICKGUIDE SIGMA
16
Selecting sequences
Allows the operator up to nine sets of all
adjustable values.
Short press: Changes to next sequence.
Long press: Opens for selecting number of
sequences. Turn (15) to choose number.
The function is off when 0 is chosen. Press
(15A) briefly to accept choice.
17
Tack welding
When this function is activated, sequence,
hotstart and slope down are off.
18
DUO Plus
TM
Pulsating wire in connection with synergic
MIG on/off (figure 1).
19
Pulse welding
MIG pulse welding on/off.
20
Selecting trigger mode
Change between 2-stroke (indicator off)
and 4-stroke (indicator on).
2-stroke: The welding process starts when
the torch trigger is activated and ends
when the torch trigger is released.
4-stroke: The welding process starts when
the torch trigger is activated and released
(hotstart is active until release of torch
trigger) and ends when the torch trigger is
activated again.
21
Watercooling (not all versions)
Indicator is on when watercooling of torch
is activated. For detail information, see
instruction manual.
PULSE
2
UK
22
Internal/external adjustment
When external adjustment is chosen, the
indicator is on.
For special configuration, see instruction
manual.
23
Wire inching
Press the key to feed the wire and adjust
the wire feed speed by turning (14)
simultaneously.
24
Gastest/IGC menu
The gas valve is open as long as you press
and hold down the key.
If IGC
®
is available, it is possible at the same
time to read the gas quantity. Turn (15)
simultaneously to adjust the value. Press
(20) while you press and hold down (24) to
switch between synergic and manual gas
adjustment. Display will switch between
values 0 = manual gas control and 1 = IGC.
21
22
23
24

Publicidad