Saber K00SB1814 Guía Del Producto página 18

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting (continued)
Problem
Possible Cause
ELECTRICAL ISSUES CON'T.:
Burner(s) will not light
Wires are loose or disconnected.
using ignitor. (See
Electronic Ignition
Wires are shorting (sparking) between
Troubleshooting also).
ignitor and electrode.
Continued.
Dead battery.
ELECTRONIC IGNITION:
No spark, no ignition noise.
No spark, some ignition noise.
Sparks, but not at electrode or at full
strength.
Burner(s) will not match
See "GAS ISSUES:" on previous page.
light.
Match will not reach
Improper method of match-lighting.
Sudden drop in gas
Out of LP gas.
flow or low flame.
Excess flow valve tripped on LP regulator.
Vapor lock at coupling nut/LP tank
connection.
Out of NG gas or NG gas line obstruction.
NG regulator lock-up
Flames blow out.
High or gusting winds
Low on LP gas.
Excess flow valve tripped.
Low on NG gas.
Flare-up.
Grease buildup.
Excessive cooking temperature.
Persistent grease fire
Grease trapped by food buildup around
burner system.
Flashback (fire in
Burner and/or burner tubes are blocked.
burner tube(s)).
One burner does not
Burner and/or burner tubes are blocked..
light from other
burner(s).
Prevention/Solution
Reconnect wires or replace electrode/wire assembly.
Replace ignitor wire/electrode assembly.
Replace with a new alkaline battery.
See Section l of Electronic Ignition System.
See Section ll of Electronic Ignition System.
See Section lll of Electronic Ignition System.
Use long-stem match (fireplace match)
See "Match-Lighting" section of Use and Care.
Check for gas in LP tank.
Turn off knobs, wait 30 seconds and light side burner. If flames are
still low, turn off knobs and LP tank valve. Disconnect regulator.
Reconnect regulator and leak-test. Turn on LP tank valve, wait 30
seconds and then light side burner.
Turn off knobs and LP tank valve. Disconnect coupling nut from tank.
Reconnect and retry.
Check NG gas supply.
Have plumber check NG gas supply pressure.
Block gusting winds.
Refill LP tank.
Refer to "Sudden drop in gas flow" above.
Check NG gas supply.
Clean burners and inside of side burner pan/firebox.
Adjust (lower) temperature accordingly.
Turn knobs to OFF. Turn gas off at LP tank. Leave lid in open
position and let fire burn out. After side burner cools, remove and
clean parts.
Turn knobs to OFF. Clean burner and/or burner tubes. See burner
cleaning section of Use and Care manual.
Turn knobs to OFF. Clean burner and/or burner tubes. See burner
cleaning section of Use and Care manual.
18

Publicidad

Tabla de contenido
loading

Productos relacionados para Saber K00SB1814

Tabla de contenido