INSTALLATION CON'T.
2. Electronic Ignition Module.
NOTE: A licensed electrician should be used to install the ignition module and make any
wiring extensions or modifications.
This side burner has been supplied with enough wire to mount the ignition module in the location shown in Figure 1. The ignition
module can be mounted in a different location by extending the switch wires and ignitor wires. Wire extensions are not provided
and should be made of materials with equivalent ratings as the switch and ignitor wiring provided with this side burner (see rating
printed on each wire). If extending the wires, take care to maintain the factory-provided connections that connect the wires to the
other side burner components. NOTE: The ignition module must be mounted so as to have easy access to the battery
compartment for battery replacement. See Figure 2. Connect wires to the small and large connections on the rear of the
ignition module. See Figure 3.
5.00"
5.00"
1 Small
Connector
Ignition Module
& Heat Shield
Figure 1
Mounting holes
EI Module
2 Large Connectors
Figure 3
1. Separate EI module from heat shield.
2. Mount heat shield using 2 screw holes supplied.
3. Assembly EI module to heat shield using nut.
4. Install battery and cap.
5. Attached wires as shown.
Heat Shield
Nut
9
-
+
Rotate cap counterclockwise
to open battery compartment.
Figure 2
Battery
Cap